VEGACAL:
Capacitive level measurement
The sensor and the wall of the container form the two electrodes of a capacitor. When the level changes, the electrical capacitance between the electrodes also changes. This change is evaluated by the electronics and converted into an output signal. Robust cable and rod versions cover a variety of applications.
The advantages
Fully insulated instrument versions also measure aggressive liquids or highly adhesive media.
Partly insulated versions perform reliable switching in powdered and granular bulk materials. The construction and quarrying industry, in particular, benefits from the sturdy build of these instruments.
Select a suitable sensor using the technical data.
» VEGACAL 62
Version
partly insulated rod
Measuring range
up to 6 m
Process fitting
thread from G¾, ¾ NPT flanges from DN 25, 1"
Materials
steel, 316L, PTFE
Process temperature
-50 … +200 °C
Process pressure
-1 … +64 bar (-100 … +6400 kPa)
SIL qualification
up to SIL2
| | » VEGACAL 63
Version
fully insulated rod
Measuring range
up to 6 m
Process fitting
thread from G¾, ¾ NPT flanges from DN 25, 1"
Process temperature
-50 … +200 °C
Process pressure
-1 … +64 bar (-100 … +6400 kPa)
SIL qualification
up to SIL2
| | » VEGACAL 64
Version
fully insulated rod
Process fitting
thread from G¾, ¾ NPT flanges from DN 25, 1"
Process temperature
-50 … +150 °C
Process pressure
-1 … +64 bar (-100 … +6400 kPa)
SIL qualification
up to SIL2
| | » VEGACAL 65
Version
partly insulated cable
Process fitting
thread from G1, 1 NPT flanges from DN 50, 1"
Process temperature
-50 … +200 °C
Process pressure
-1 … +64 bar (-100 … +6400 kPa)
SIL qualification
up to SIL2
| | » VEGACAL 66
Version
fully insulated cable
Process fitting
thread from G1, 1 NPT flanges from DN 50, 2"
Process temperature
-50 … +150 °C
Process pressure
-1 … +40 bar (-100 … +4000 kPa)
SIL qualification
up to SIL2
| | » VEGACAL 69
Measuring range
up to 4 m
Process fitting
flanges from DN 50, 2"
Process temperature
-50 … +100 °C
Process pressure
-1 … +2 bar (-100 … +200 kPa)
SIL qualification
up to SIL2
| | |
» VEGACAL 62
Version
partly insulated rod
Measuring range
up to 6 m
Process fitting
thread from G¾, ¾ NPT flanges from DN 25, 1"
Materials
steel, 316L, PTFE
Process temperature
-50 … +200 °C
Process pressure
-1 … +64 bar (-100 … +6400 kPa)
SIL qualification
up to SIL2
| | » VEGACAL 65
Version
partly insulated cable
Process fitting
thread from G1, 1 NPT flanges from DN 50, 1"
Process temperature
-50 … +200 °C
Process pressure
-1 … +64 bar (-100 … +6400 kPa)
SIL qualification
up to SIL2
| | » VEGACAL 67
Process fitting
thread from G1½, 1½ NPT flanges from DN 50, 2"
Werkstoffe
Steell, 316L, PTFE, ceramic
Process temperature
-50 … +400 °C
Process pressure
-1 … +16 bar (-100 … +1600 kPa)
SIL qualification
up to SIL2
| | |