VEGAPULS 65
Radar sensor for continuous level measurement
Application area
VEGAPULS 65 is suitable for measurement of liquids in smaller vessels under ordinary process conditions. Application possibilities in virtually all areas of industry.
Advantages
Non-contact measurement
Simple mounting
Wear and maintenance-free
Unaffected by pressure, temperature, gas and dust
High measuring accuracy
Function
Extremely short microwave pulses are emitted via the antenna system to the measured product, reflected by the product surface and received again by the antenna system. The time from emission to reception of the signals is proportional to the level. A special evaluation procedure ensures a reliable and precise measurement.
Measuring range |
up to 35 m |
|
Process fitting |
G1½A or flange |
|
Process temperature |
-40 … +150 °C |
|
Process pressure |
-1 … +16 bar (-100 … +1600 kPa) |
|
Accuracy |
+/- 8 mm |
|
Emitting frequency |
C-Band |
|
|
Documentation
|
Product catalogue
|
|
| Radar |
  |
  |
  |
  |
  |
  |
 |
 |
 |
 |
 |
 |
 |
|
Product information
|
|
|
Level measurement in solids and in liquids: VEGAPULS 61, 62, 63, 65, 66
|
  |
  |
  |
  |
  |
  |
 |
 |
 |
 |
 |
 |
 |
|
Specification sheet - VEGAPULS 65
|
4 … 20 mA/HART - two-wire
|
  |
  |
  |
  |
  |
  |
  |
 |
 |
 |
 |
 |
 |
4 … 20 mA/HART - four-wire
|
  |
  |
  |
  |
  |
  |
  |
 |
 |
 |
 |
 |
 |
Profibus PA
|
  |
  |
  |
  |
  |
  |
  |
 |
 |
 |
 |
 |
 |
Foundation Fieldbus
|
  |
  |
  |
  |
  |
  |
  |
 |
 |
 |
 |
 |
 |
|
|
Operating instructions - VEGAPULS 65
|
| 4 … 20 mA/HART - two-wire
|
|
  |
  |
  |
  |
  |
  |
  |
  |
  |
  |
 |
 |
 |
4 … 20 mA/HART - two-wire
Hardware version ≥ 2.0.0 - Software version ≥ 4.0.0 |
|
  |
  |
  |
  |
  |
  |
  |
 |
 |
  |
 |
 |
 |
| 4 … 20 mA/HART - four-wire
|
|
  |
  |
  |
  |
  |
  |
  |
  |
  |
 |
 |
 |
 |
|
|
  |
  |
  |
  |
  |
  |
  |
  |
  |
 |
 |
 |
 |
|
|
  |
  |
  |
  |
  |
  |
  |
  |
  |
 |
 |
 |
 |
|
|
Drawings - VEGAPULS 65
|
| Flange - for socket 100 mm, 200 mm |
  |
  |
  |
 |
 |
 |
| Thread - PVDF - for socket 50 mm |
  |
  |
  |
 |
 |
 |
| Thread - PVDF - for socket 100 mm, 200 mm |
  |
  |
  |
 |
 |
 |
| Thread - VA - for socket 100 mm, 200 mm |
 |
 |
 |
 |
 |
 |
| Bolting DIN11851 DN50 - for socket 50 mm |
  |
  |
  |
 |
 |
 |
| Tri-Clamp 2” - for socket 50 mm |
  |
  |
  |
 |
 |
 |
|
|
Drawings - Housing
|
| Plastic, cable entry M20 x 1.5 |
  |
  |
  |
  |
  |
 |
| Plastic, cable entry ½ NPT |
  |
  |
  |
  |
  |
 |
| Aluminium, cable entry M20 x 1.5 |
  |
  |
  |
  |
  |
 |
| Aluminium, cable entry ½ NPT |
  |
  |
  |
 |
 |
 |
| Aluminium double chamber, cable entry M20 x 1.5 |
  |
  |
  |
  |
  |
 |
| Aluminium double chamber, cable entry ½ NPT |
  |
  |
  |
 |
 |
 |
| Stainless steel (electropolished) |
  |
  |
  |
  |
  |
 |
| Stainless steel (precision casting) |
  |
  |
  |
  |
  |
 |
| Stainless steel (precision casting) double chamber, cable entry M20 x 1.5 |
  |
  |
  |
 |
 |
 |
|