VEGAPULS:
Level measurement with Radar
In non-contact level measurement with radar, the sensor sends microwave signals towards the medium from above. The surface of the medium reflects the signals back in the direction of the sensor. Using the received microwave signals, the sensor determines the distance to the product surface and calculates the level from it.
The advantages
The measurement is not influenced by temperature, pressure or product properties.
Select a suitable sensor using the technical data.
» VEGAPULS WL 61
Measuring range
up to 15 m
Process fitting
thread G1½ mounting strap compression flanges from DN 80, 3"
Process temperature
-40 … +80 °C
Process pressure
-1 … +2 bar (-100 … +200 kPa)
Measuring precision
±2 mm
| | » VEGAPULS 61
Measuring range
up to 35 m
Process fitting
thread G1½, 1½ NPT mounting strap compression flanges from DN 80, 3"
Process temperature
-40 … +80 °C
Process pressure
-1 … +3 bar (-100 … +300 kPa)
Measuring precision
+/- 2 mm
SIL qualification
up to SIL2
| | » VEGAPULS 62
Measuring range
up to 35 m
Process fitting
thread from G1½, 1½ NPT flanges from DN 50, 2"
Process temperature
-200 … +450 °C
Process pressure
-1 … +160 bar (-100…+16000 kPa)
Measuring precision
+/- 2 mm
SIL qualification
up to SIL2
| | » VEGAPULS 63
Measuring range
up to 35 m
Process fitting
hygienic fittings boltings flanges from DN 50, 2"
Process temperature
-200 … +200 °C
Process pressure
-1 … +16 bar (-100 … +1600 kPa)
Measuring precision
+/- 2 mm
SIL qualification
up to SIL2
| | » VEGAPULS 65
Measuring range
up to 35 m
Process fitting
thread from G1½, 1½ NPT flanges from DN 50, 2"
Process temperature
-40 … +150 °C
Process pressure
-1 … +16 bar (-100 … +1600 kPa)
Measurement accuracy
+/- 8 mm
SIL qualification
up to SIL2
| | » VEGAPULS 66
Measuring range
up to 35 m
Process fitting
flanges up to DN 50, 2"
Process temperature
-60 … +400 °C
Process pressure
-1 … +160 bar (-100 … +16000 kPa)
Measurement accuracy
+/- 8 mm
SIL qualification
up to SIL2
| | |
» VEGAPULS 67
Measuring range
up to 15 m
Process fitting
mounting strap compression flanges from DN 80, 3"
Process temperature
-40 … +80 °C
Process pressure
-1 … +2 bar (-100 … +200 kPa)
Measurement accuracy
+/- 2 mm
SIL qualification
up to SIL2
| | » VEGAPULS SR 68
Measuring range
Up to 30 m
Process fitting
thread from G1½, 1½ NPT flanges from DN 50, 2"
Process temperature
-40 ... +250 °C
Process pressure
-1 ... +100 bar
(100 ... +10000 kPa)
Measuring precision
+/- 2 mm
| | » VEGAPULS 68
Measuring range
up to 75 m
Process fitting
thread from G1½, 1½ NPT flanges from DN 50, 2"
Process temperature
-200 … +450 °C
Process pressure
-1 … +160 bar (-100 … +16000 kPa)
Measurement accuracy
+/- 2 mm
SIL qualification
up to SIL2
| | |