Australia

Change country
Imprint Search Sitemap Contact
Home » Downloads » Approvals » Guided Microwave » Explosion protection
Current devices
Former devices
Sensor Mode of protection
ATEX Ex-zone0
VEGAFLEX 61, 62, 63, 65, 66, 67
- 4 … 20 mA/HART - Two-Wire
II 1G, II 1/2 G, II2G Ex ia IIC T6
intrinsically safe
Safety Instructions
703,83 KB 703,83 KB 703,83 KB 703,83 KB
Certificate
1256,83 KB 1421,23 KB
VEGAFLEX 61, 62, 63, 65, 66, 67
- 4 … 20 mA/HART - Two-Wire
- 4 … 20 mA/HART - Four-Wire
- Profibus PA
- Foundation Fieldbus
II 1/2 G, II 2G Ex d ia IIC T6
Intrinsically safe; pressure-tight encapsulation
Safety Instructions
424,13 KB 797,08 KB 799,27 KB 795,34 KB
Certificate
2311,55 KB 2474,62 KB
VEGAFLEX 61, 62, 63, 65, 66, 67
- Profibus PA
- Foundation Fieldbus
II 1G, II 1/2 G, II2G Ex ia IIC T6
intrinsically safe
Safety Instructions
282,38 KB 274,92 KB 704,39 KB 704,39 KB
Certificate
1619,52 KB 1484,11 KB
ATEX Ex-Zone2
VEGAFLEX 61, 62, 63, 65, 66, 67
- 4 … 20 mA/HART - Two-Wire
II 3G Ex nA II T5...T1 X
Safety Instructions
197,76 KB 183,67 KB 188,30 KB 167,17 KB
VEGAFLEX 61, 62, 63, 65, 66, 67
- Profibus PA
II 3G Ex nA II T5...T1 X
Safety Instructions
198,33 KB 183,60 KB 189,04 KB 176,98 KB
VEGAFLEX 61, 62, 63, 65, 66, 67
- Foundation Fieldbus
II 3G Ex nA II T5...T1 X
Safety Instructions
198,18 KB 173,10 KB 179,47 KB 167,52 KB
ATEX StEx-zone20
VEGAFLEX 61, 62, 63, 66
- 4 … 20 mA/HART - Two-Wire
- 4 … 20 mA/HART - Four-Wire
- Profibus PA
- Foundation Fieldbus
- GX: II 1/2D, II 2D Ex tD A20/21, A21
IP66  T...
- CK: II 1/2D, II 2D Ex tD A20/21, A21
IP66 T...+
II 1G, II 1/2G, II 2G Ex ia IIC T6
Safety Instructions
190,01 KB 182,42 KB 934,90 KB 933,17 KB
Certificate
5120,93 KB 5228,79 KB
IECEx
VEGAFLEX 61, 62, 63, 65, 66, 67
- 4 … 20 mA/HART - Two-Wire
- 4 … 20 mA/HART - Four-Wire
Ex d ia IIC  T6
intrinsic safety, pressure-tight encapsulation
Safety Instructions
1302,32 KB
VEGAFLEX 61, 62, 63, 65, 66, 67
- 4 … 20 mA/HART - Two-Wire
Ex ia IIC T6
intrinsically safe
Safety Instructions
1106,62 KB
VEGAFLEX 61, 62, 63, 66
- 4 … 20 mA/HART - Two-Wire
- Profibus PA
- Foundation Fieldbus
- 4 … 20 mA/HART - Four-Wire
Ex tD A20/21 IP66 T... or
Ex tD A21 IP66 T...
Safety Instructions
446,72 KB
FM
VEGAFLEX 61, 62, 63, 65, 66, 67
- 4 … 20 mA/HART - Two-Wire
- Profibus PA
- Foundation Fieldbus
FM (IS) CL I, II, III, DIV 1, GP ABCDEFG
Safety Instructions
895,78 KB
VEGAFLEX 61, 62, 63, 65, 66, 67
- 4 … 20 mA/HART - Two-Wire
FM (XP-IS) CL I, II, III, DIV 1,
GP ABCDEFG
Safety Instructions
858,94 KB
VEGAFLEX 61, 62, 63, 65, 66, 67
- 4 … 20 mA/HART - Two-Wire
- Profibus PA
- Foundation Fieldbus
FM (NI) CL I, DIV 2, GP ABCD
(DIP) CL II, III, DIV 1, GP EFG
Safety Instructions
425,13 KB
CSA
VEGAFLEX 61, 62, 63, 65, 66, 67
- 4 … 20 mA/HART - Two-Wire
- Profibus PA
- Foundation Fieldbus
CSA (IS) CL I, II, III, DIV 1, GP ABCDEFG
Safety Instructions
687,81 KB
VEGAFLEX 61, 62, 63, 65, 66, 67
- 4 … 20 mA/HART - Two-Wire
CSA (XP-IS) CL I, II, III, DIV 1,
GP ABCDEFG
Safety Instructions
3114,87 KB
VEGAFLEX 61, 62, 63, 65, 66, 67
- 4 … 20 mA/HART - Two-Wire
- Profibus PA
- Foundation Fieldbus
- 4 … 20 mA/HART - Four-Wire
CSA (NI) CL I, DIV 2, GP ABCD
(DIP) CL II, III, DIV 1, GP EFG
Safety Instructions
576,05 KB