VEGAFLEX 63 Level sensor according to the measuring principle of the guided microwave (TDR) For universal use in liquids - Setup without adjustment - Independent of product features - Insensitive to vapour and buildup - Proven ECHOFOX signal processing - Adjustment with PLICSCOM or PC - Instrument from the plics® family Approval without ATEX II 1G, 1/2G, 2G EEx ia IIC T6 ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG ATEX II 1/2G, 2G EEx d ia IICT6 Version / Temperature Cable ø6mm PFA insulated with gravity weight / -40...150°C Rod ø10mm PFA insulated / -40...150°C Process fitting / Material Flange DN50PN40, DIN2501 / PTFE-plattiert Flange DN80PN40, DIN2501 / PTFE-plattiert Flange DN100PN16, DIN2501 / PTFE-plattiert Flange 2" 150lb RF, ANSI B16.5 / PTFE-plattiert Flange 3" 150lb RF, ANSI B16.5 / PTFE-plattiert Flange 4" 150lb RF, ANSI B16.5 / PTFE-plattiert Tri-Clamp 2" PN16 / PTFE-TFM 1600 Bolting DN40PN40 DIN11851 / PTFE-TFM 1600 Electronics two-wire 4...20mA/HART® four-wire 4...20mA/HART® Profibus PA Foundation Fieldbus Housing / Protection Plastic / IP66/IP67 Aluminium / IP66/IP68 (0,2bar) Aluminium double chamber / IP66/IP68 (0,2bar) StSt (electropolished) 316L / IP66/IP68 (0,2bar) Cable entry / Plug connection M20x1,5 / without ½ NPT / without Indicating/adjustment module (PLICSCOM) without top mounted