VEGABAR 61 Pressure transmitter with isolating diaphragm For pressure measurements of very corrosive or hot products - Unaffected by foam generation - Unaffected by fluctuations of the dielectric value - Deviation in characteristics 0.1% - Adjustment with PLICSCOM or PC - Free-of-charge customer-specific adjustment - Instrument from the plics® family Approval without Ship approval ATEX II 1G, 1/2G, 2G EEx ia IIC T6 ATEX II 1/2D, 2D IP6X T Process fitting / Material Flange DN25PN40 Form C,DIN2501 / 316L Flange DN50PN40 Form C,DIN2501 / 316L Flange DN80PN40 mit Tube 50mm,ø76 / 316L Flange 1"150lb RF,ANSI B16.5 / 316L Flange 2"150lb RF,ANSI B16.5 / 316L Tube isolator with clamp connector 2" / 316L Bolting DN50PN25,DIN11851 / 316L Isolating liquid / Temperature Silikone oil KN2.2 / -40...150°C (Pabs <1bar-40...150°C) HT-oil KN3.2+cooling. / -10...400°C(Pabs<1bar-10..200°C) Halocarbon oil KN21 / -40...150°C (Pabs <1bar-40...80°C) Diaphragm material 316L Hastelloy C276 Tantal PTFE Pressure / Measuring range rel. / 0...2,5 bar (0...250 kPa) rel. / 0...100 bar (0...10000 kPa) rel. / -1...10 bar (-100...1000 kPa) rel. / -1...60 bar (-100...6000 kPa) abs. / 0...5 bar (0...500 kPa) Electronics 4...20mA/HART® Profibus PA Foundation Fieldbus Housing / Protection Plastic / IP66/IP67 Aluminium / IP66/IP67 Aluminium double chamber / IP66/IP67 StSt (electropolished) 316L /IP66/IP67 PE-cable axial IP68, ext. housing plastic IP65 Cable entry / Plug connection M20x1,5 / without ½NPT / without Indicating/adjustment module (PLICSCOM) without mounted