VEGAPULS 62 Microwave sensor for continuous level measurement with horn antenna or with mounted 1/2" standpipe (K-band) Particularly suitable for storage tanks or process vessels for measurement of virtually all substances under arduous process conditions - Non-contact measurement - Easy mounting - Accuracy +/- 3mm - Proven ECHOFOX signal processing - Adjustment with PLICSCOM or PC - Instrument from the plics® family Approval without Ship approval ATEX II 1G, 1/2G, 2G EEx ia IIC T6 ATEX II 1/2G, 2G EEx d ia IIC T6 Version / Material with horn antenna ø 40 mm / 316L with horn antenna ø 48 mm / 316L with horn antenna ø 75 mm / 316L with horn antenna ø 95 mm / 316L with ½" standpipe/ 316L Process fitting / Material Thread G¾A PN40 / 316L Thread ¾NPT PN40 / 316L Thread G1½A PN40 / 316L Thread 1½NPT PN40 / 316L Flange DN50PN40 Form C,DIN2501 / 316L Flangeh DN80PN40 Form C,DIN2501 / 316L Flange DN100PN16 Form C,DIN2501 / 316L Flange DN150PN16 Form C,DIN2501 / 316L Flange 2"150lb RF,ANSI B16.5 / 316L Flange 3"150lb RF,ANSI B16.5 / 316L Flange 4"150lb RF,ANSI B16.5 / 316L Flange 6"150lb RF,ANSI B16.5 / 316L Seal / Process temperature FKM (Viton) / -40...130°C Kalrez 6375 / -20...130°C FKM (Viton) / -40...200°C (not with steam) Kalrez 6375 / -20...200°C Electronics Two-wire 4...20mA HART® Four wire 4...20mA HART® Profibus PA Foundation Fieldbus Housing / Protection Plastic/ IP66/IP67 Aluminium / IP66/IP68 (0,2bar) Aluminium double chamber / IP66/IP68 (0,2bar) StSt (electropolished) 316L / IP66/IP68 (0,2bar) Cable entry / Plug connection M20x1,5 / without ½NPT / without Indicating/adjusment module (PLICSCOM) without oben eingebaut