VEGA

Special waste treatment

Special waste treatment

Receiving chambers for special waste

Special waste can include varnishes, paints and thinners as well as acids, lyes and emulsions. These materials accumulate in the chemical industry, in metal processing and in vehicle construction. In special waste treatment, substances harmful to the environment are converted into ecologically compatible substances, i.e. they are rendered suitable for long-term deposition. Before treatment begins, the liquid special waste is collected in receiving chambers. There, level measurements guarantee automated, monitored operation of the system and thus protect personnel and environment

Level measurement with VEGAPULS 63

The radar sensor VEGAPULS 63 is the optimal solution for special waste with different chemical and physical characteristics. It works reliably under difficult process conditions like steam, temperature fluctuations and agitated surfaces.

Maximum signal with VEGACAP 63

The maximum signal delivered by a fully PTFE-insulated, capacitive level switch VEGACAP 63 prevents overfilling in the receiving chambers.

Leak detection with VEGASWING 63

VEGASWING 63 has proved to be a very good leakage detector in the containers, which are double walled for safety reasons. In combination with the signal conditioning instrument VEGATOR 636, it fulfils the requirements of SIL2.

» VEGAPULS 63

Measuring range
up to 35 m  
Process fitting
hygienic fittings
boltings
flanges from DN 50, 2"
Process temperature
-200 … +200 °C  
Process pressure
-1 … +16 bar
(-100 … +1600 kPa)
Measuring precision
+/- 2 mm
SIL qualification
up to SIL2

» VEGACAP 63

Version
fully insulated rod
Measuring range
up to 6 m
Process fitting
thread from G¾, ¾ NPT
flanges from DN 50, 2"
Materials
316L, PE, PTFE
Process temperature
-50 … +200 °C
Process pressure
-1 … +64 bar
(-100 … +6400 kPa)

» VEGASWING 63

Version
tube extension up to 6 m
Materials
316L, ECTFE, PFA
Hastelloy, enamel
Process fitting
thread from G¾, ¾ NPT
flanges from DN 25, 1"
hygienic fittings
Process temperature
-50 … +250 °C 
Process pressure
-1 … +64 bar
(-100 … +6400 kPa) 
SIL qualification
up to SIL2