Sprache/Language
DE
|
EN
VEGA international
change country
Products
Applications
Downloads
Services
Company
News
Loading
Home
»
Products
»
Level
»
Radar
Products
Innovation
Level
Radar
VEGAPULS WL 61
VEGAPULS 61
VEGAPULS 62
VEGAPULS 63
VEGAPULS 65
VEGAPULS 66
VEGAPULS 67
VEGAPULS SR 68
VEGAPULS 68
Guided microwave
Ultrasonic
Capacitive
Hydrostatic
Radiation-based
Switching
Pressure
Density
Flow
Signal conditioning
Software
VEGAPULS:
Level measurement with Radar
Series
Selection
criteria
Application area
Measuring principle
Liquids
Liquids
» VEGAPULS WL 61
Measuring range
up to 15 m
Process fitting
DN80, mounting strap or flange
Process temperature
-40 … +80 °C
Process pressure
-1 … +2 bar
(-100 … +200 kPa)
Measuring precision
±2 mm
» VEGAPULS 61
Measuring range
up to 35 m
Process fitting
G1½A, mounting strap or flange
Process temperature
-
40 … +80 °C
Process pressure
-1 … +2 bar
(-100 … +200 kPa)
Measuring precision
+/- 2 mm
SIL qualification
up to SIL2
» VEGAPULS 62
Measuring range
up to 35 m
Process fitting
thread or flange
Process temperature
-200 … +450 °C
Process pressure
-1 … +160 bar
(-100…+16000 kPa)
Measuring precision
+/- 2 mm
SIL qualification
up to SIL2
» VEGAPULS 63
Measuring range
up to 35 m
Process fitting
flange or hygienic connection
Process temperature
-200 … +200 °C
Process pressure
-1 … +16 bar
(-100 … +1600 kPa)
Measuring precision
+/- 2 mm
SIL qualification
up to SIL2
» VEGAPULS 65
Measuring range
up to 35 m
Process fitting
G1½A or flange
Process temperature
-
40 … +150 °C
Process pressure
-1 … +16 bar
(-100 … +1600 kPa)
Measurement accuracy
+/- 8 mm
SIL qualification
up to SIL2
» VEGAPULS 66
Measuring range
up to 35 m
Process fitting
flange
Process temperature
-60 … +400 °C
Process pressure
-1 … +160 bar
(-100 … +16000 kPa)
Measurement accuracy
+/- 8 mm
SIL qualification
up to SIL2
Solids
Solids
» VEGAPULS 67
Measuring range
up to 15 m
Process fitting
mounting strap, flange
Process temperature
-40 … +80 °C
Process pressure
-1 … +2 bar
(-100 … +200 kPa)
Measurement accuracy
+/- 2 mm
SIL qualification
up to SIL2
» VEGAPULS SR 68
Measuring range
Up to 30 m
Process fitting
Thread from G1½ A, 1½ NPT
Flanges from DN 50, 2"
Process temperature
-40 ... +250 °C
Process pressure
-1 ... +100 bar
Measuring precision
+/- 2 mm
SIL qualification
up to SIL2
» VEGAPULS 68
Measuring range
up to 75 m
Process fitting
G1½A or flange
Process temperature
-200 … +450 °C
Process pressure
-1 … +160 bar
(-100 … +16000 kPa)
Measurement accuracy
+/- 2 mm
SIL qualification
up to SIL2
finder
configurator