Propane bullets
Level measurement in propane bullets
Process data
    Measuring task:
    
    Level measurement
        Measuring point:
    
    Bullet tank
        Measuring range up to:
    
    4 m
        Medium:
    
    Liquid propane
        Process temperature:
    
    -40 … +50 °C
        Process pressure:
    
    +3 … +10 bar
        Special challenges:
    
    Low dielectric constant
Application
Propane, a flammable, colourless and odourless gas, is one of the many types of liquefied petroleum gases (LPG) that exist. It is produced from natural gas via a special refining process. Propane is compressed, liquefied and stored in pressure vessels so that it does not return to a gaseous state. To ensure optimal storage, reliable level measurement is required.
                    Your benefit
Reliable
                                Redundant measurement increases plant availability and plant safety
                            Cost effective
                                Maintenance-free operation
                            User friendly
                                Easy installation and setup
                            Recommended products
 
                                            VEGAFLEX 81 and magnetic level indicator
Guided wave radar and magnetic level indicator for reliable level measurement
- Redundant measurement through the combination of guided radar sensor and magnetic level indicator
- Measurement is unaffected by low dielectric constant
- Equipment can be isolated from vessel for service without affecting the process
Measuring range - Distance
                                                            75 m
                                                            Process temperature
                                                            -60 ... 200 °C
                                                            Process pressure
                                                            -1 ... 40 bar
                                                             
                                            VEGADIF 85
Differential pressure transmitter for redundant measurement
- High reliability through integrated overload diaphragm
- Measurement of very low differential pressures through high precision measured value detection
Measuring range - Pressure
                                                            -40 ... 40 bar
                                                            Process temperature
                                                            -90 ... 400 °C
                                                            Process pressure
                                                            -1 ... 400 bar