Storage tank for beer bottling
Level measurement and point level detection in the supply tank of a bottling machine
Process data
Measuring task:
Level measurement and point level detection
Measuring point:
Vessel
Measuring range up to:
1 m
Medium:
Beer
Process temperature:
+4 … +60 °C
Process pressure:
0 … +2.5 bar
Special challenges:
Small tank
Application
Beer is continuously delivered into the filler supply tank of the bottling machine. Reliable level measurement is important for an optimal filling process. A point level sensor is used to also prevent dry run.
Your benefit
Reliable
Certified materials according to FDA and EC 1935/2004 regulations
Cost effective
Continuous filling process thanks to reliable measurement
User friendly
Simple installation and setup
Recommended products

VEGAPOINT 21
Capacitive point level sensor as dry run protection
- Good cleanability, because sensor is only a minimal installation in the container
- Reliable detection of the medium, independent of buildup
- 360° display of the switch status
Measuring range - Distance
-
Process temperature
-40 ... 115 °C
Process pressure
-1 ... 25 bar

VEGAPULS 6X
Non-contact level measurement with radar in the filling machine
- Reliable measurement at all temperatures
- Flange with encapsulated antenna system allows optimal CIP cleaning
- Small sensor can be mounted even in very small vessels
Measuring range - Distance
120 m
Process temperature
-196 ... 450 °C
Process pressure
-1 ... 160 bar