Close
email public

FIBERTRAC 31

Radiometric sensor for continuous level measurement

Flexible detector


FIBERTRAC 31

Application area

The flexible detector is used on round vessels and vessels with conical outlet and is suitable for measurement of liquids, solids, slurries and suspensions. Due to its thin, flexible scintillator cross-section, FIBERTRAC 31 can be easily adapted to round vessels.
The FIBERTRAC 31 is a radiation-based sensor with flexible plastic sensing element for continuous measurement of liquids and bulk solids. It is suitable for level measurement under extreme process temperatures, in case of critical product features or aggressive products. The FIBERTRAC 31 delivers precise measuring results even under hardest application conditions.

Your benefit

  • Simple mounting on round and conical vessels through flexible detector
  • High plant availability through non-contact measurement
  • Cost saving through use of only one sensor up to 7 m measuring range

Configure product

Configure product

All documents and software for this product can be found in our Download Center.

Show all downloads
Application
Technical specifications
Documentation
Accessories
Configure product

Other applications

Coke drums

Coke drums

Density, level measurement and point level detection in coke drums

To the application

Distillation column

Level and pressure measurement in the distillation unit

Level and pressure measurement in the distillation unit

To the application

Continuous catalyst regeneration

Level measurement and point level detection of catalyst

Level measurement and point level detection of catalyst

To the application

Fluid catalytic cracking unit

Density, level measurement and point level detection in the reactor

Density, level measurement and point level detection in the reactor

To the application
Technical specifications
Measuring range - Distance
  • 7 m [Meter - Foot]
Process temperature
  • - [°C - °F]
Process pressure
  • - [Bar - kPa - psi]
Accuracy
  • ± 0.5 %
Density
  • Density
Materials, wetted parts
  • No wetted material
Threaded connection
  • Mounting from outside via supplied mounting brackets
Seal material
  • no media contact
Housing material
  • Aluminium
  • Stainless steel (precision casting)
Protection rating
  • IP66/IP67
Output
  • Profibus PA
  • Foundation Fieldbus
  • Four-wire: 4 … 20 mA/HART
Ambient temperature
  • -20 ... 50 °C
Approvals
Scope
  • ATEX / Europe
  • CSA / Canada
  • FM / USA
  • EAC (GOST) / Russia
  • IEC / worldwide
  • NEPSI / China
  • INMETRO / Brazil
  • CCOE / India
  • KTL Korea
Explosion protection
  • Intrinsic safety "i"
  • Flameproof enclosure "d"
  • Dust explosion protection through housing "t"
Overfill protection
  • WHG
SIL qualification
  • SIL2
Display & adjustment
Adjustment
  • PLICSCOM
  • PC, PACTware and DTM
  • HART-Communicator
  • Software (e. g. AMS™, PDM)
  • Bluetooth
Indication
  • Display/adjustment module PLICSCOM
  • VEGADIS 81
  • VEGADIS 82

Drawing generator

Generate 2D and 3D drawings for your specific configuration.

Configure Now

Product catalog

Radiometric

    • EN
    • DE
    • CS
    • ES
    • FR
    • IT
    • NL
    • PL
    • PT
    • TR
    • ZH
Download

Product information

ProTrac

    • EN
    • US
    • DE
    • ES
    • FR
    • IT
    • NL
    • PL
    • PT
    • TR
    • ZH
Download

Specification sheet

FIBERTRAC 31

4 … 20 mA/HART - four-wire

    • EN
    • US
    • DE
    • ES
    • FR
    • IT
    • NL
    • PT
    • TR
    • ZH
Download

Operating instructions

FIBERTRAC 31

4 … 20 mA/HART - four-wire

    • EN
    • DE
    • CS
    • DA
    • ES
    • FI
    • FR
    • HU
    • IT
    • KK
    • KO
    • NL
    • NO
    • PL
    • PT
    • SV
    • TR
    • UK
    • ZH
Download

Supplementary instructions

Air cooling - FIBERTRAC 31

Accessory

    • EN
    • DE
    • ES
    • FR
    • IT
    • NL
    • PT
    • TR
    • ZH
Download

Supplementary instructions

Water cooling - FIBERTRAC 31

Accessory

    • EN
    • DE
    • ES
    • FR
    • IT
    • KK
    • NL
    • PT
    • TR
    • UK
    • ZH
Download

Drawing generator

Generate 2D and 3D drawings for your specific configuration.

Configure Now

Further downloads for this product

All documents and software for this product can be found in our Download Center.

Show all downloads
Controllers
Indicating instruments
Wireless communication
Separating instruments
Overvoltage protection instruments
Accessory
Spare parts

VEGAMET 141

1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation

Show Product

VEGAMET 142

2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation

Show Product

VEGAMET 341

1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation

Show Product

VEGAMET 342

2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation

Show Product

VEGAMET 841

1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

Show Product

VEGAMET 842

2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

Show Product

VEGAMET 861

1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

Show Product

VEGAMET 862

2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation

Show Product

VEGAMET 624

VEGAMET625 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren.png	352 KB		 VEGAMET624 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren

Measured value indication, simple control functions such as remote enquiry of measured values for a 4 ... 20 mA/HART sensor

Show Product

VEGAMET 625

VEGAMET625 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren

Measured value indication, simple control functions such as remote enquiry of measured values for two HART sensors

Show Product

VEGAMET 391

VEGAMET391 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren

Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry

Show Product

VEGATOR 141

Single channel signal conditioning instrument for level detection - 4 … 20 mA

Transmission of 4 ... 20 mA signals for level signalling

Show Product

VEGATOR 142

Double channel signal conditioning instrument for level detection - 4 … 20 mA

Transmission of 4 ... 20 mA signals for level signalling

Show Product

VEGASCAN 693

Signal conditioning instrument for up to 15 HART sensors

Measured value indication and remote enquiry of measured data for up to 15 HART sensors

Show Product
Our recommendation

PLICSCOM

PLICSCOM Steckbares Anzeige- und Bedienmodul

Measured value indication and adjustment of plics® sensors

Show Product

Bluetooth USB adapter

Wireless adjustment of sensors and instruments via Bluetooth

Show Product

VEGADIS 81

Remote measurement value indication and adjustment of plics® sensors

Show Product

VEGADIS 82

External measured value display and adjustment for 4 ... 20 mA/HART sensors

Show Product

VEGADIS 176

Remote display for use in 4 ... 20 mA current loop

Show Product

Magnetic pen for display/adjustment module PLICSCOM

PLICSCOM Magnet Pen

Magnetic pen for on-site adjustment

Show Product

PLICSMOBILE T81

externe-GSM-GPRS-Funkeinheit

Measured data enquiry and remote parameter adjustment for a HART sensor

Show Product

VEGATRENN 141

Einkanaliger Speisetrenner für 4 … 20 m/HART-Sensoren

Single channel separator for 4 … 20 m/HART sensors

Show Product

VEGATRENN 142

Zweikanaliger Speisetrenner für 4 … 20 m/HART-Sensoren

Double channel separator for 4 … 20 m/HART sensors

Show Product

VEGATRENN 151

Einkanaliger Trennübertrager in Zweileitertechnik für 4 … 20 mA-Sensoren

Single channel separator in two-wire technology for 4 … 20 mA sensors

Show Product

VEGATRENN 152

Zweikanaliger Trennübertrager in Zweileitertechnik für 4 … 20 mA-Sensoren

Double channel separator in two-wire technology for 4 … 20 mA sensors

Show Product

Overvoltage protection B 63-32

Überspannungsschutz B63

Overvoltage protection for Profibus PA and Foundation Fieldbus circuits

Show Product

Overvoltage protection B 63-48

Ueberspannungsschutz-B63

Overvoltage protection for two-wire circuits

Show Product

Overvoltage protection B 62-30 W

Ueberspannungsschutz B62-30W in Zweileitertechnik Profibus-PA Foundation-Fieldbus-Stromkreise

Overvoltage protection for Profibus PA and Foundation Fieldbus circuits

Show Product

Overvoltage protection B 62-36 G

Ueberspannungsschutz B62-30G Versorgungs- und Signalleitungen in 4-20 mA-Stromkreisen

Overvoltage protection for two-wire circuits

Show Product

Water/Air cooling FIBERTRAC 31

Cooling FIBERTRAC Air

Active water/air cooling system for radiation-based sensors

Show Product

Electronics FIBERTRAC 30 series

Loading device data
Configuration is being created
Loading configuration
Want to pick up where you left off?
Your latest configuration
{{lastConfiguration.code}}
{{getLastConfigurationDate()}}
Open configuration
An error occured while sending the last request. Please try again. ({{httpErrorStatusCode}})

An error has occurred

An error occurred when starting the configurator. We have documented the error and are working on it.
Please try again later. Alternatively you can contact us directly.

Thank you very much for your understanding.

Settings
{{subGroup.subGroupName}}
Go to: {{activeGroup.nextGroup.groupName}}