VEGABAR 82

Pressure transmitter with ceramic measuring cell

The all-rounder with ceramic measuring cell


Application area

Universally applicable pressure transmitter. The ceramic measuring cell is resistant to temperature shocks. Can be combined with any other sensor of VEGABAR Series 80 for electronic differential pressure measurement.

The VEGABAR 82 pressure transmitter can be used universally for the measurement of gases, vapours and liquids. Substances such as sand can be handled easily thanks to the abrasion-resistant ceramic measuring cell. The VEGABAR 82 offers maximum reliability. The transmitter can be used in all industries. The simple connection of VEGABAR series 80 sensors as electronic differential pressure opens new possibilities for the measurement of differential pressures.

Your benefit

  • Low maintenance costs thanks to wear-free ceramic measuring cell
  • High plant availability through maximum overload and vacuum resistance of the ceramic measuring cell
  • Measurement down to the last drop through smallest measuring ranges with high accuracy

Configure product

Configure product
Application
Technical specifications
Documentation
Accessories
Configure product

The robust, all-round pressure sensor with ceramic measuring cell

The pressure sensor VEGABAR 82 is the robust all-rounder with an innovative flush mounted ceramic measuring cell that VEGA manufactures itself, as a full-range supplier of pressure instrumentation. A real highlight: the ceramic pressure sensor is resistant to thermal shock. The versatile standard instrument handles temperatures up to 150° C. The extremely high overload factor of 200 is unique to the market. This pressure sensor covers 80% of all applications in the process industry. With its oil-free ceramic CERTEC® measuring cell it is well equipped for use in all areas of industry:

  • Monitoring of feed pressure in sewage pipelines
  • Overload-resistant level and gauge pressure measurement in pressurized batch vessels
  • Level measurement of paper pulp level in bleaching towers, to protect against dry-run damage to the discharge pumps
  • Monitoring of negative pressure in distillation columns (down to absolute vacuum)

Technical specifications
Measuring range - Distance
-
Measuring range - Pressure
-1 ... 100 bar
Process temperature
-40 ... 150 °C
Process pressure
-1 ... 100 bar
Accuracy
0.05 %
Materials, wetted parts
PVDF
316L
Alloy C22 (2.4602)
PP
1.4057
1.4410
Alloy C276 (2.4819)
Duplex (1.4462)
Titanium Grade 2 (3.7035)
Threaded connection
≥ G½, ≥ ½ NPT
Flange connection
≥ DN15, ≥ ½"
Hygenic fittings
Clamp ≥ 1" - DIN32676, ISO2852
Slotted nut ≥ DN25 - DIN 11851
hygienic fitting with tension flange DN32
hygienic fitting F40 with compression nut
DRD connection ø 65 mm
SMS 1145 DN51
SMS DN38
Swagelok VCR screwing
Varivent G125
Varivent N50-40
for NEUMO BioControl D50 PN16 / 316L
Seal material
EPDM
FKM
FFKM
Housing material
Plastic
Aluminium
Stainless steel (precision casting)
Stainless steel (electropolished)
Protection rating
IP 66/IP 68 (0.2 bar)
IP 66/IP 67
IP 66/IP 68 (1 bar)
IP 66/IP 68 (25 bar)
IP 69 K
Output
Profibus PA
Foundation Fieldbus
4 … 20 mA
4 … 20 mA/HART - two-wire
Modbus
Slave electronics for electronic differential pressure
Ambient temperature
-40 ... 80 °C
Approvals
Scope
ATEX / Europe
CSA / Canada
FM / USA
EAC (GOST) / Belarus
EAC (GOST) / Kazakhstan
EAC (GOST) / Russia
IEC / worldwide
INMETRO / Brazil
CCOE / India
Explosion protection
Intrinsic safety Ex ia
Pressure-tight encapsulation Ex d
Protection through housing St Ex
Foodstuffs/Pharma
3A
EHEDG
FDA
Drinking water
EG1935/2004
Ship approval
ABS
BV
CCS
DNV
GL
LR
RINA
Overfill protection
WHG
VLAREM II
SIL qualification
SIL2
Display & adjustment
Adjustment
PLICSCOM
PC, PACTware and DTM
HART-Communicator
Software (e. g. AMS™, PDM)
Indication
Display/adjustment module PLICSCOM
VEGADIS 81
VEGADIS 82

Product information

VEGABAR 81, 82, 83

    • EN
    • DE
    • ES
    • FR
    • IT
    • NL
    • PT
    • RU
    • TR
    • US
    • ZH
Download

Operating instructions

VEGABAR 82

4 … 20 mA - two-wire

    • EN
    • DE
    • CS
    • ES
    • FR
    • HU
    • IT
    • KK
    • NL
    • PL
    • PT
    • RU
    • TR
    • UK
    • ZH
Download

Specification sheet

VEGABAR 82

4 … 20 mA - two-wire

    • EN
    • DE
    • ES
    • FR
    • IT
    • NL
    • PT
    • RU
    • TR
    • US
    • ZH
Download

Product catalog

Process pressure

    • EN
    • DE
    • CS
    • ES
    • FR
    • IT
    • NL
    • PT
    • RU
    • TR
    • ZH
Download

Further downloads for this product

All documents and software for this product can be found in our Download Center.

Show all downloads
Indicating instruments
Controllers
Wireless communication
Separating instruments
Overvoltage protection instruments
Components
Accessory
Spare parts
Our recommendation

PLICSCOM

Measured value indication and adjustment of plics® sensors

Show Product

Bluetooth USB adapter

Wireless adjustment of sensors and instruments via Bluetooth

Show Product

VEGADIS 81

Remote measurement value indication and adjustment of plics® sensors

Show Product

VEGADIS 82

External measured value display and adjustment for 4 ... 20 mA/HART sensors

Show Product

VEGADIS 176

Remote display for use in 4 ... 20 mA current loop

Show Product

Magnetic pen for display/adjustment module PLICSCOM

Magnetic pen for on-site adjustment

Show Product

VEGAMET 381

Measured value display and simple control functions

Show Product

VEGAMET 391

Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry

Show Product

VEGAMET 624

Measured value indication, simple control functions such as remote enquiry of measured values for a 4 ... 20 mA/HART sensor

Show Product

VEGAMET 625

Measured value indication, simple control functions such as remote enquiry of measured values for two HART sensors

Show Product

VEGASCAN 693

Measured value indication and remote enquiry of measured data for up to 15 HART sensors

Show Product

VEGATOR 141

Transmission of 4 ... 20 mA signals for level signalling

Show Product

VEGATOR 142

Transmission of 4 ... 20 mA signals for level signalling

Show Product

PLICSMOBILE T81

Measured data enquiry and remote parameter adjustment for a HART sensor

Show Product

WirelessHART-Adapter

Emitting unit for wireless transmission of measured values ​​and remote parameter adjustment/diagnosis (single channel)

Show Product

WirelessHART-Gateway

Receiving unit for wireless transmission of measured values ​​and remote parameter adjustment/diagnosis (multichannel)

Show Product

WirelessHART accessory

Mounting kit and extra battery

Show Product

VEGATRENN 141

Single channel separator for 4 … 20 m/HART sensors

Show Product

VEGATRENN 142

Double channel separator for 4 … 20 m/HART sensors

Show Product

VEGATRENN 151

Single channel separator in two-wire technology for 4 … 20 mA sensors

Show Product

VEGATRENN 152

Double channel separator in two-wire technology for 4 … 20 mA sensors

Show Product

Overvoltage protection B 81-35

Pluggable overvoltage protection for supply and signal cables

Show Product

Overvoltage protection B 63-32

Overvoltage protection for Profibus PA and Foundation Fieldbus circuits

Show Product

Overvoltage protection B 63-48

Overvoltage protection for two-wire circuits

Show Product

Overvoltage protection B 62-30 W

Overvoltage protection for Profibus PA and Foundation Fieldbus circuits

Show Product

Overvoltage protection B 62-36 G

Overvoltage protection for two-wire circuits

Show Product

VEGACONNECT

Interface adapter between PC and VEGA instruments

Show Product

VEGABOX 03

Modem antenna

Ethernet switch

up to 8 RS45 pluggable

Show Product

Profibus PA/DP segment coupler

Simple segment coupler for up to 93.75 kbit/s DP-side

Show Product

Ball valve fitting PASVE

The ball valve fitting PASVE™ is used for mounting of VEGABAR 54, 82 pressure transmitters with process fitting "Thread 1" suitable for PASVE.

Show Product

Siphon

Siphons according to DIN 16282 are cooling zones for protection of the pressure transmitters against too hot process media.

Show Product

Valve

Valves are used as shut-off device when connecting pressure transmitters to the process.

Show Product

Welded socket with accessory VEGABAR series 80

Welded sockets are used to connect the sensors to the process.

Show Product

Antenna extension PLICSMOBILE

Electronics VEGABAR series 80

Process component VEGABAR 82

PLICSMOBILE plug connector with SMA connection

Electronics PLICSMOBILE series 80

Configurator is starting