Close

VEGA Controls Ltd.

Kendal House, Victoria Way

RH15 9NF BURGESS HILL
WEST SUSSEX

United Kingdom

Tel.: +44 1444 870055

Fax: +44 1444 870080

Telephone consultation

You’d like to talk with an expert? You’re looking for the ideal sensor for your requirements? Then call us. We’ll be glad to help you select the right instrument.

You’ll be connected with your VEGA consultant via our switchboard:

+44 1444 870055

Service hotline

If you need service, feel free to call our 24-hour hotline, available seven days a week. Only normal call charges are incurred:

+49 1805 85 85 50

VEGASON 62

Ultrasonic sensor for continuous level measurement

VEGASON 62
VEGASON 62

Application area

Liquids and bulk solids in small vessels

The VEGASON 62 is an ultrasonic sensor for continuous level measurement of liquids and bulk solids. Typical applications are the measurement of liquids in storage vessels or open basins. The sensor is also suitable for the detection of bulk solids in small vessels or silos. Application areas can be found in all industries. The non-contact measuring principle is unaffected by product features and allows a setup without medium.

Your benefit

  • Price-favourable solution for simple applications
  • Maintenance-free operation through non-contact measuring principle
  • Reliable measurement independent of product features

Technical data

Measuring-range---Distance
8 m
Process-temperature
-40 ... 80 °C
Process-pressure
-0.2 ... 2 bar
Accuracy
± 10 mm / ± 0.4"
Materials,-wetted-parts
PVDF
Threaded-connection
≥ G2, ≥ 2 NPT
Seal-material
  • EPDM
  • FKM
Housing-material
  • Plastic
  • Aluminium
  • Stainless steel (precision casting)
  • Stainless steel (electropolished)
Protection-rating
  • IP 66/IP 68 (0.2 bar)
  • IP 66/IP 67
  • IP 66/IP 68 (1 bar)
Output
  • Profibus PA
  • Foundation Fieldbus
  • 4 … 20 mA/HART - two-wire
  • 4 … 20 mA/HART - four-wire
Ambient-temperature
-40 ... 80 °C

Product configuration

Configure product

Documentation & Software

appropriate to VEGASON 62

Accessories

appropriate to VEGASON 62

PLICSCOM

Measured value indication and adjustment of plics® sensors

Protection-rating
IP 20/IP 40
Ambient-temperature
-15 ... 70 °C

Bluetooth USB adapter

Wireless adjustment of sensors and instruments via Bluetooth

Version
Bluetooth Smart
Ambient-temperature
-40 ... 85 °C
Forecast
Forecast

VEGADIS 81

Remote measurement value indication and adjustment of plics® sensors

Housing-material
Plastic
+2 other
Protection-rating
IP 66/IP 68 (0.2 bar)
+1 other
Ambient-temperature
-15 ... 70 °C

VEGADIS 82

External measured value display and adjustment for 4 ... 20 mA/HART sensors

Housing-material
Plastic
+2 other
Protection-rating
IP 66/IP 68 (0.2 bar)
+1 other
Ambient-temperature
-15 ... 70 °C

VEGADIS 176

Remote display for use in 4 ... 20 mA current loop

Protection-rating
IP 20/IP 65
Ambient-temperature
-10 ... 60 °C

Magnetic pen for display/adjustment module PLICSCOM

Magnetic pen for on-site adjustment

VEGAMET 381

Measured value display and simple control functions

Protection-rating
IP 20/IP 40
Input
1 x 4 … 20 mA sensor input
Output
1 x 0/4 … 20 mA current output
+2 other

VEGAMET 391

Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry

Protection-rating
IP 20/IP 65
Input
1 x 4 … 20 mA/HART sensor input
+1 other
Output
1 x 0/4 … 20 mA current output
+3 other

VEGAMET 624

Measured value indication, simple control functions such as remote enquiry of measured values for a 4 ... 20 mA/HART sensor

Protection-rating
IP 20/IP 30
Input
with transmitter power supply
+1 other
Output
1 x fail safe relay
+4 other

VEGAMET 625

Measured value indication, simple control functions such as remote enquiry of measured values for two HART sensors

Protection-rating
IP 20/IP 30
Input
2 x 4 … 20 mA/HART sensor input with transmitter power supply (only HART capable sensors)
Output
1 x fail safe relay
+4 other

VEGASCAN 693

Measured value indication and remote enquiry of measured data for up to 15 HART sensors

Protection-rating
IP 20/IP 30
Input
up to 15 HART-capable sensors
+1 other
Output
1 x fail safe relay
+2 other

VEGATOR 141

Transmission of 4 ... 20 mA signals for level signalling

Protection-rating
IP 20
Input
1 x 4 … 20 mA sensor input
Output
1 x operating relay (SPDT)
+1 other

VEGATOR 142

Transmission of 4 ... 20 mA signals for level signalling

Protection-rating
IP 20
Input
2 x 4 … 20 mA sensor input
Output
2 x operating relay (SPDT)

PLICSMOBILE T61

Remote enquiry of measured data and remote parameter adjustment for one plics® sensor

Housing-material
Plastic
Protection-rating
IP 66/IP 67
Input
1 x plics® sensor

WirelessHART-Adapter

Emitting unit for wireless transmission of measured values ​​and remote parameter adjustment/diagnosis (single channel)

Housing-material
Plastic
+1 other
Protection-rating
IP 66
Ambient-temperature
-40 ... 80 °C

WirelessHART-Gateway

Receiving unit for wireless transmission of measured values ​​and remote parameter adjustment/diagnosis (multichannel)

Protection-rating
IP 65
Ambient-temperature
-20 ... 60 °C

WirelessHART accessory

Mounting kit and extra battery

VEGATRENN 141

Single channel separator for 4 … 20 m/HART sensors

Protection-rating
IP 20
Input
1 x 4 … 20 mA/HART sensor input
Output
1 x 4 … 20 mA

VEGATRENN 142

Double channel separator for 4 … 20 m/HART sensors

Protection-rating
IP 20
Input
2 x 4 … 20 mA sensor input
Output
2 x 4 ... 20 mA

VEGATRENN 151

Single channel separator in two-wire technology for 4 … 20 mA sensors

Protection-rating
IP 20
Input
1 x 4 … 20 mA/HART sensor input
Output
1 x 4 … 20 mA

VEGATRENN 152

Double channel separator in two-wire technology for 4 … 20 mA sensors

Protection-rating
IP 20
Input
2 x 4 … 20 mA sensor input
Output
2 x 4 ... 20 mA

Overvoltage protection B 63-32

Overvoltage protection for Profibus PA and Foundation Fieldbus circuits

Protection-rating
IP 66
Ambient-temperature
-40 ... 85 °C

Overvoltage protection B 63-48

Overvoltage protection for two-wire circuits

Protection-rating
IP 66
Ambient-temperature
-40 ... 85 °C

Overvoltage protection B 62-30 W

Overvoltage protection for Profibus PA and Foundation Fieldbus circuits

Housing-material
Plastic
+1 other
Protection-rating
IP 20/IP 65
Ambient-temperature
-40 ... 60 °C

Overvoltage protection B 62-36 G

Overvoltage protection for two-wire circuits

Housing-material
Plastic
+1 other
Protection-rating
IP 20/IP 65
Ambient-temperature
-40 ... 60 °C

Separator type KFD0-CS-Ex1.51P

Galvanic separation of intrinsically safe 4 ... 20 mA circuits

Protection-rating
IP 20
Input
1 x 4 … 20 mA sensor input active
Ambient-temperature
-20 ... 60 °C

VEGACONNECT

Interface adapter between PC and VEGA instruments

Housing-material
Plastic
Protection-rating
IP 40
Ambient-temperature
-20 ... 60 °C

VEGABOX 03

Protection-rating
IP 66/IP 68 (0.2 bar)
Ambient-temperature
-20 ... 70 °C

Modem antenna

Ethernet switch

up to 8 RS45 pluggable

Protection-rating
IP 20

Profibus PA/DP segment coupler

Simple segment coupler for up to 93.75 kbit/s DP-side

Protection-rating
IP 20
Ambient-temperature
-20 ... 60 °C

Housing adapter VEGASON 61,62,63

Electronics VEGASON 61, 62, 63, 64, 65, 66

Process component VEGASON 62