Pool condenser

Level measurement in the pool condenser

Level measurement in the pool condenser
Level measurement in the pool condenser

Process data

Measuring task
Level measurement
Measuring point
Tank
Measuring range up to
4 m
Medium
Ammonium carbamate, ammonia, carbon dioxide
Process temperature
+170 ... +180 °C
Process pressure
+130 … +160 bar
Special challenges
Highly aggressive media

Application

In a pool condenser, ammonium carbamate is produced from a mixture of carbon dioxide and ammonia under high pressure. The ammonium carbamate, in turn, is the starting material for the subsequent main reaction in the production of urea. To ensure safe operation of this high-pressure application, a continuous, dependable level measurement solution is needed.

Your benefit

Reliable
Reliable measurement in highly corrosive media
Cost effective
Special high-resistance steel construction for long operational life
User friendly
Safe operation under all operating conditions