VEGADIF 85

Differential pressure measurement for all media

VEGADIF 85
VEGADIF 85

Application area

Differential pressure transmitter with metal measuring diaphragm

The VEGADIF 85 is a universal differential pressure transmitter for measurement of liquids, gases and vapours. Typical application areas are level measurement in pressurized vessels as well as flow measurement in combination with effective pressure transmitters. Further applications are pressure monitoring on filters as well as density and interface measurements.

Your benefit

  • High reliability through integrated overload diaphragm
  • Measurement of very low differential pressures through high precision measured value detection
  • Multivariable sensor through integrated measurement of the absolute pressure

Technical data

Measuring range - Pressure
-40 ... 40 bar
Process temperature
-40 ... 120 °C
Process pressure
-1 ... 400 bar
Accuracy
Accuracy
Materials, wetted parts
  • 316L
  • Tantalum
  • Alloy C276 (2.4819)
  • Monel
Threaded connection
¼ - 18 NPT
Flange connection
≥ DN32, ≥ 1⅜"
Seal material
  • EPDM
  • FKM
  • Copper
Housing material
  • Plastic
  • Aluminium
  • Stainless steel (precision casting)
  • Stainless steel (electropolished)
Protection rating
  • IP 66/IP 68 (0.2 bar)
  • IP 66/IP 67
  • IP 66/IP 68 (1 bar)
Output
  • 4 … 20 mA/HART
  • Profibus PA
  • Foundation Fieldbus
  • 4 … 20 mA
Ambient temperature
-40 ... 80 °C

Configurator

Configure product

VEGA Recommends

Valve block

Add a three or five way manifold block for isolating and testing your differential pressure transmitter.

Product details
PLICSCOM now with Bluetooth!

Product configuration

Configure product

Documentation & Software

appropriate to VEGADIF 85

Accessories

appropriate to VEGADIF 85

PLICSCOM

Measured value indication and adjustment of plics® sensors

Protection rating
IP 20/IP 40
Ambient temperature
-15 ... 70 °C

Bluetooth USB adapter

Wireless adjustment of sensors and instruments via Bluetooth

Version
Bluetooth Smart
Ambient temperature
-40 ... 85 °C
Forecast
Forecast

VEGADIS 81

Remote measurement value indication and adjustment of plics® sensors

Housing material
Plastic
+2 other
Protection rating
IP 66/IP 67
Ambient temperature
-20 ... 70 °C

VEGADIS 82

External measured value display and adjustment for 4 ... 20 mA/HART sensors

Housing material
Plastic
+2 other
Protection rating
IP 66/IP 67
Ambient temperature
-20 ... 70 °C

VEGADIS 176

Remote display for use in 4 ... 20 mA current loop

Protection rating
IP 20/IP 65
Ambient temperature
-10 ... 60 °C

Magnetic pen for display/adjustment module PLICSCOM

Magnetic pen for on-site adjustment

VEGAMET 381

Measured value display and simple control functions

Protection rating
IP 20/IP 40
Input
1 x 4 … 20 mA sensor input
Output
1 x 0/4 … 20 mA current output
+2 other

VEGAMET 391

Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry

Protection rating
IP 20/IP 65
Input
1 x 4 … 20 mA/HART sensor input
+1 other
Output
1 x 0/4 … 20 mA current output
+3 other

VEGAMET 624

Measured value indication, simple control functions such as remote enquiry of measured values for a 4 ... 20 mA/HART sensor

Protection rating
IP 20/IP 30
Input
with transmitter power supply
+1 other
Output
1 x fail safe relay
+4 other

VEGAMET 625

Measured value indication, simple control functions such as remote enquiry of measured values for two HART sensors

Protection rating
IP 20/IP 30
Input
2 x 4 … 20 mA/HART sensor input with transmitter power supply (only HART capable sensors)
Output
1 x fail safe relay
+4 other

VEGASCAN 693

Measured value indication and remote enquiry of measured data for up to 15 HART sensors

Protection rating
IP 20/IP 30
Input
up to 15 HART-capable sensors
+1 other
Output
1 x fail safe relay
+2 other

VEGATOR 141

Transmission of 4 ... 20 mA signals for level signalling

Protection rating
IP 20
Input
1 x 4 … 20 mA sensor input
Output
1 x operating relay (SPDT)
+1 other

VEGATOR 142

Transmission of 4 ... 20 mA signals for level signalling

Protection rating
IP 20
Input
2 x 4 … 20 mA sensor input
Output
2 x operating relay (SPDT)

VEGATRENN 141

Single channel separator for 4 … 20 m/HART sensors

Protection rating
IP 20
Input
1 x 4 … 20 mA/HART sensor input
Output
1 x 4 … 20 mA

VEGATRENN 142

Double channel separator for 4 … 20 m/HART sensors

Protection rating
IP 20
Input
2 x 4 … 20 mA sensor input
Output
2 x 4 ... 20 mA

VEGATRENN 151

Single channel separator in two-wire technology for 4 … 20 mA sensors

Protection rating
IP 20
Input
1 x 4 … 20 mA/HART sensor input
Output
1 x 4 … 20 mA

VEGATRENN 152

Double channel separator in two-wire technology for 4 … 20 mA sensors

Protection rating
IP 20
Input
2 x 4 … 20 mA sensor input
Output
2 x 4 ... 20 mA

Overvoltage protection B 63-32

Overvoltage protection for Profibus PA and Foundation Fieldbus circuits

Protection rating
IP 66
Ambient temperature
-40 ... 85 °C

Overvoltage protection B 63-48

Overvoltage protection for two-wire circuits

Protection rating
IP 66
Ambient temperature
-40 ... 85 °C

Overvoltage protection B 62-30 W

Overvoltage protection for Profibus PA and Foundation Fieldbus circuits

Housing material
Plastic
+1 other
Protection rating
IP 20/IP 65
Ambient temperature
-40 ... 60 °C

Overvoltage protection B 62-36 G

Overvoltage protection for two-wire circuits

Housing material
Plastic
+1 other
Protection rating
IP 20/IP 65
Ambient temperature
-40 ... 60 °C

Ventilation valve

Vent valves allow venting of the measuring chambers of differential pressure transmitters.

Oval flange adapter

Oval flange adapters according to IEC 61518 enable the connection of pipelines with ½ NPT to differential pressure transmitters.

Mounting angle for VEGADIF

Mounting angle for wall or tube mounting.

Valve block

Valves are used as shut-off device when connecting differential pressure transmitters to the process as well as for pressure equalisation of the measuring chambers during setup.

Closing screw

Closing plugs are used to cover the open side of measuring chambers of pressure transmitters.

Replacement screw for valve block

Process component VEGADIF 85

Electronics VEGADIF series 80

VEGACONNECT

Interface adapter between PC and VEGA instruments

Housing material
Plastic
Protection rating
IP 40
Ambient temperature
-20 ... 60 °C

VEGABOX 03

Protection rating
IP 66/IP 68 (0.2 bar)
Ambient temperature
-20 ... 70 °C

Ethernet switch

up to 8 RS45 pluggable

Protection rating
IP 20

Profibus PA/DP segment coupler

Simple segment coupler for up to 93.75 kbit/s DP-side

Protection rating
IP 20
Ambient temperature