关闭

Deaerator

Level measurement in the deaerator

过程数据

测量任务:
Level measurement
测量点:
Tank
测量范围至:
1.2 m
介质:
Paper suspension
过程温度:
+20 … +50 °C
过程压力:
-0.8 … 0 bar
特殊挑战:
Foaming, turbulent surface due to gas emissions, low level with vacuum

应用范围

The approach flow system connects the stock preparation facility with the paper machine. Here, the pulp for the paper machine is diluted to the required consistency. Additionally, the approach flow system ensures a smooth flow of stock. A particularly important element is the stock deaerator upstream of the headbox. It removes any entrained air under vacuum to ensure a constant, smoothly running process. For effective performance, the stock deaerator always has to be filled to a predefined, millimetre-exact level.

您的获益

Reliable
Dry run protection for the headbox pump
Cost effective
Low-cost solution through use of electronic differential pressure
User friendly
Easy mounting without mounting brackets and capillary tubes