Reactor
Level measurement in an aluminium powder suspension reactor
Process data
Measuring task:
Level measurement
Measuring point:
Reactor
Measuring range up to:
1.2 m
Medium:
Aluminium powder suspension
Process temperature:
0 … +130 °C
Process pressure:
0 … +0.3 bar
Special challenges:
Low dielectric constant, confined spaces, strong turbulence on the product surface, condensation
Application
Aluminium powder suspension is an intermediate for titanium sponge production. In the reactor, vanadium oxide trichloride is removed from the aluminium powder suspension. When the aluminium powder suspension is fed into the reactor, strong turbulence arises on the product surface. To optimize the process, the level in the reactor must be accurately measured and monitored.
Your benefit
Reliable
Reliable measurement despite small dielectric constants
Cost effective
Reliable measurement of the entire reactor volume
User friendly
Simple mounting and setup
Recommended products
VEGAPULS 6X
Non-contact level measurement with radar in the reactor
- Good signal focussing allows use in tight spaces
- Unaffected by condensate and deposits on the antenna
- Strong focussing allows reliable measurement at close range and at the bottom of the tank as well as in media with low dielectric constant
- Maintenance-free through non-contact measurement
Measuring range - Distance
120 m
Process temperature
-196 ... 450 °C
Process pressure
-1 ... 160 bar