Clinker silo
Level measurement and point level detection in clinker silos
Process data
    Measuring task:
    
    Level measurement and point level detection
        Measuring point:
    
    Silo
        Measuring range up to:
    
    30 m
        Medium:
    
    Clinker
        Process temperature:
    
    -40 … +200 °C
        Process pressure:
    
    0 … 0 bar
        Special challenges:
    
    Dust, abrasion, high temperatures 
Application
After the raw meal is burned, the emerging clinker of varying consistency is stored for further processing. The silos are filled and emptied through different openings. Continuous operation of the subsequent production processes is ensured by level measurement and point level detection.
                    Your benefit
Reliable
                                Reliable measurement despite high temperatures
                            Cost effective
                                Optimal stocks enable continuous production
                            User friendly
                                Maintenance-free operation
                            Recommended products
 
                                            VEGAPULS 6X
Level measurement with radar in clinker silos
- Exact measurement right to the bottom of the discharge funnel thanks to small beam angle
- High measurement certainty, unaffected by dust and temperature changes
- Maintenance-free through non-contact measurement
Measuring range - Distance
                                                            120 m
                                                            Process temperature
                                                            -196 ... 450 °C
                                                            Process pressure
                                                            -1 ... 160 bar
                                                             
                                            VEGACAP 65
Capacitive point level detection in clinker silos
- Robust construction ensures a long service life
- Reliable measurement, unaffected by buildup
- Cut to length cable probes allow high flexibility
Measuring range - Distance
                                                            -
                                                            Process temperature
                                                            -50 ... 200 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                             
                    
Close