Storage container for rennet
Level measurement and point level detection in the storage container
Process data
    Measuring task:
    
    Level measurement and point level detection
        Measuring point:
    
    Vessel
        Measuring range up to:
    
    3 m
        Medium:
    
    Rennet
        Process temperature:
    
    +20 … +95 °C
        Process pressure:
    
    0 … +2.5 bar
        Special challenges:
    
    Aseptic process fittings, temperature fluctuations
Application
The rennet is needed to coagulate the milk when making cheese. It is stored in a storage container and metered out into the cheese vat as needed. Reliable level and point Level detection are essential to ensure that sufficient rennet is on hand for continuous cheese production.
                    Your benefit
Reliable
                                Certified hygienic design (3A/EHEDG) and approved materials according to EC 1935/2004 and FDA
                            Cost effective
                                Certified hygienic design of the sensors reduces cleaning time
                            User friendly
                                Simple installation and setup
                            Recommended products
Solution 1
                Solution 2
         
                                            VEGABAR 83
Pressure transmitter for hydrostatic level measurement
- Reliable measurement at all temperatures through mechanical decoupling
- Good cleanability thanks to flush-mounted installation
- Robust measuring cell guarantees long-term stability
Measuring range - Distance
                                                            -
                                                            Measuring range - Pressure
                                                            -1 ... 1000 bar
                                                            Process temperature
                                                            -40 ... 200 °C
                                                             
                                            VEGAPOINT 23
Capacitive level sensor as overfill protection
- Compact design facilitates cleaning
- Reliable detection of the medium, independent of buildup
- 360° display of the switching status
Measuring range - Distance
                                                            -
                                                            Process temperature
                                                            -40 ... 115 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                             
                                            VEGAPULS 42
Non-contact radar level measurement in storage tanks in the lab
- Simple automation and integration options thanks to IO-Link
- Maintenance-free operation thanks to non-contact measuring principle
- 360° status display for quick and easy recognition of process status
- Compact design allows installation even in very small vessels
Measuring range - Distance
                                                            15 m
                                                            Process temperature
                                                            -40 ... 130 °C
                                                            Process pressure
                                                            -1 ... 16 bar
                                                             
                                            VEGAPOINT 23
Capacitive level sensor as overfill protection
- Compact design facilitates cleaning
- Reliable detection of the medium, independent of buildup
- 360° display of the switching status
Measuring range - Distance
                                                            -
                                                            Process temperature
                                                            -40 ... 115 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                             
                                    
                             
                             
                                                    
                                             
                                            
Close