Hydrogen compressor
Pressure measurement in the hydrogen compressor
Process data
    Measuring task:
    
    Pressure measurement
        Measuring point:
    
    Pipeline
        Measuring range up to:
    
    1000 bar
        Medium:
    
    Compressed hydrogen
        Process temperature:
    
    -40 ... +50 °C
        Process pressure:
    
    0 … +1,000 bar
        Special challenges:
    
    Diffusion, high pressures
Application
Compressors are of great importance in the hydrogen supply chain. By compressing the hydrogen molecules, a higher energy density of the extremely light gas can be achieved. For that reason, the gas is compressed to a pressure of several hundred bar for storage – typically 350 and 700 bar. This is very important for the refuelling process at hydrogen filling stations, for example. To ensure efficient and safe operation, the pressure must be monitored at various points in hydrogen compressors.
                    Your benefit
Reliable and safe
                                Reliable pressure monitoring ensures safe operation of the facility
                            Cost effective
                                Accurate measurement for efficient hydrogen production
                            User friendly
                                Easy installation with very small process fittings
                            Recommended products
 
                                            VEGABAR 83
Pressure sensor for pressure measurement in the compression chamber
- High long-term stability thanks to metallic measuring cell of hydrogen-suitable stainless steel
- Reliable measurement due to oil-free, thin-film measuring cell
- Optional gold coating of the diaphragm reduces diffusion
- Simple installation in existing pipelines
Measuring range - Distance
                                                            -
                                                            Measuring range - Pressure
                                                            -1 ... 1000 bar
                                                            Process temperature
                                                            -40 ... 200 °C
                                                             
                                            VEGABAR 29
Pressure measurement in the compressor pipelines
- Reliable measurement of hydrogen up to 1,000 bar
- Simple setup and commissioning via Bluetooth
- Reliable measured values thanks to fast response time
Measuring range - Pressure
                                                            -1 ... 1000 bar
                                                            Process temperature
                                                            -40 ... 130 °C
                                                            Accuracy
                                                            0.3 %
                                                             
                                    
                             
                                                    
                                            
Close