When just a few drops can make all the difference – how radar level measurement brings safety and security to laboratories
Non-contact level measurement with VEGAPULS 42 – precision that builds trust. The radar sensor can detect even the smallest changes of the mobile phases in storage vessels.
In modern laboratories, every process is meticulously planned and the degree of automation is high. Nevertheless, many level checks are still carried out manually – or with outdated technology.
The problem: These older methods are prone to errors because they rely on floats or weighing systems.
Since measurement errors in the laboratory can have serious consequences, QuACX developed QuACX:smartRMS, an intelligent monitoring system based on VEGA radar technology. At its core: VEGAPULS 42, a compact level sensor, that measures contactlessly – with an accuracy of down to two millimetres.
What makes this level sensor so special? It sees what’s invisible! Even right through steam, foam or filter attachments.
Measurement technology that knows exactly what the laboratory needs
Even through filter attachments, VEGAPULS 42 monitors the mobile phases and detects the smallest volume changes in the waste drum – non-contact measurement certainty without compromise.
VEGAPULS 42 is no ordinary sensor. With its tightly focused 12° measuring beam, it scans the liquids in bottles with narrow necks – without touching them. Thanks to its measurement accuracy of ±2 mm, the radar sensor detects even the slightest changes in volume.
Its radar-based technology works even where other measuring methods reach their limits and fail.
At QuACX, up to six sensors simultaneously monitor storage bottles and waste containers. They communicate with each other via IO-Link, exchange data and react to changes – virtually like a team. This teamwork is made possible by simple integration via IO-Link, which allows for one-time parameterisation. And these settings can be easily transferred to other instruments, saving time and effort when adjusting or expanding the system.
The bright LED ring of the integrated 360° status display shows at a glance if everything is running smoothly or if intervention is required – even from a distance or from different viewing angles. And the best part: The level sensors are maintenance-free, validatable and fully compliant with GMP and FDA requirements.
When, thanks to precise level measurement, laboratory processes run like clockwork
Every analysis run is documented, every result released, every process step retraced. That’s exactly why reliable measurement data is so crucial.
The QuACX solution meets the same quality standards as large-scale pharmaceutical processes – only in miniature format.
Before each run: a kind of “line clearance.” Afterwards: precise weighing of the substances. Finally: automated measurement – and a level monitoring system that silently watches in the background.
VEGAPULS 42 is not just a measuring instrument. It’s the safety net for the entire system – invisible, but indispensable.
What happens when level measurement fails?
Many different malfunctions can interfere with the measurement process in HPLC (High-Performance Liquid Chromatography) systems and even damage device components. To understand why QuACX relies on radar, just take a look at the following table, which provides an overview of frequent events and their possible effects on operation, measuring results and system service life:
- Air enters the pump - Unstable flow, pressure fluctuations, inaccurate retention times
- Cavitation in the pump head - Mechanical wear on pistons, seals and valves
- One-way valves no longer function correctly - Reduced flow rate, equipment failure or error message
- Pump seals dry out - Overheating, rapid wear, seal replacement necessary
- Air in the column - Dryout of the stationary phase, poorer separation performance, shorter service life
- Air bubbles in the detector - Signal interference, spikes, signal loss
- Interruption of flow during measurement - Loss or shift of peaks, incorrect quantification
All these risks can be avoided – with a precise, continuous level measuring system that never gets tired.
The advantages of radar technology – measurably better
The VEGAPULS 42 radar sensor in combination with QuACX:smartRMS – where precision and safety merge into an intelligent system.
Automated control, high compatibility and secure operation, combined with precise radar instrumentation – the QuACX solution QuACX:smartRMS hits the nail on the head. The following table shows the most important functions and the resulting benefits in the HPLC environment:
✔ Early detection of critical levels - No more surprise HPLC malfunctions
✔ Automated equipment control - No human intervention necessary
✔ Retention of qualification - Validated operation is maintained
✔ Highest measurement accuracy thanks to radar technology - Unaffected by colour, foaming or vapours
✔ Compatibility with common HPLC systems - Easy integration into existing infrastructure
✔ Safe handling of solvent waste - Protection for people, equipment and the environment
Who QuACX:smartRMS is made for
Radar level measurement demonstrates its strengths wherever precision and process reliability are crucial.
The system is particularly suitable for these users:
- Quality control laboratories in the pharmaceutical industry with GMP/GLP standards
- R&D laboratories in the chemical industry and in life sciences
- Analytical service providers with high throughput
- GMP/GLP-regulated laboratory environments
For these users, VEGAPULS 42 means: More security, less work and costs, absolute control.
When technology takes responsibility
VEGAPULS 42 proves that smart measurement technology is more than just automation. It protects equipment, processes – and sometimes even people.
Because when everything functions properly, when not a single drop overflows and no column dries out, that’s more than just technology at work. It’s trust.
And the confidence that QuACX has gained with VEGAPULS 42 – measuring point by measuring point, night after night.
Related industries
Pharmaceutical industry
Chemical industry
Products
Related posts
Safety, hygiene and quality management – VEGA sensors fulfil the requirements of the pharmaceutical industry
Read more
Measurement technology in the production of pharmaceutical active ingredients: How ChemCon achieves maximum precision with VEGA sensors
Read more
State-of-the-art measurement technology for safe chemical logistics: VEGA equips new chemical tank farm with instrumentation
Read more
Reliable instruments for challenging applications – How measurement technology secures the chemical industry
Read more
VEGAPULS 42 – radar measurement technology in compact form
Read more
Radar sensors with strong focusing ensure more precise values in continuous level measurement
Read more
Compact radar sensors without dead zone deliver reliable level values in small vessels
Read more
VEGAPULS 69 radar sensor measures the level reliably in small dosing vessels
Read more
VEGA sensors handle complex measuring tasks in pharmaceuticals production
Read more
Radar technology can now be used even in small containers
Read moreExport this article
Download as PDFShare this article
Comments ({{comments.length}})
{{getCommentAuthor(comment, "Anonymous")}} {{comment.timestamp | date : "dd.MM.yyyy HH:mm" }}
{{comment.comment}}