Adipic acid mixing tank
Level measurement and point level detection in adipic acid mixing tank
Process data
    Measuring task:
    
    Level measurement and point level detection
        Measuring point:
    
    Mixing tank
        Measuring range up to:
    
    2 m
        Medium:
    
    Adipic acid
        Process temperature:
    
    -40 … +50 °C
        Process pressure:
    
    0 … 0 bar
        Special challenges:
    
    Aggressive medium
Application
Adding adipic acid to the lime milk increases the effectiveness of the desulfurization process in the absorber. This is done by mixing adipic powder with water in the mixing tank. This acid lowers operating costs because it reduces the amount of lime milk required. Various measurement systems ensure optimal control of the mixing ratio.
                    Your benefit
Reliable
                                Reliable, service-proven technology
                            Cost effective
                                Minimal costs for maintenance and servicing
                            User friendly
                                Simple setup and commissioning
                            Recommended products
 
                                            VEGACAL 63
The capacitive level sensor monitors the level in the mixing vessel
- High chemical resistance with PTFE coating
- Long service life, low maintenance requirements
- Cost savings through simple installation and robust construction
- Measurement over the entire probe length, includes SIL2 approval
 
Measuring range - Distance
                                                            6 m
                                                            Process temperature
                                                            -50 ... 200 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                             
                                            VEGASWING 63
The coated vibrating level switch reliably prevents tank overfilling
- Product-independent switching point ensures millimetre-exact detection of the limit level
- Minimal costs for maintenance and servicing
- Available in various materials, includes Ex, WHG and SIL2 approval
 
Process temperature
                                                            -50 ... 250 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                            Version
                                                            Standard
                                                                    Hygienic applications
                                                                    with gas-tight leadthrough
                                                                    with tube extension
                                                                    with temperature adapter
                                                             
                                    
                             
                                                    
                                            