Tank feeder
Level measurement and point level detection in the tank feeder
Process data
    Measuring task:
    
    Level measurement and point level detection
        Measuring point:
    
    Tank
        Measuring range up to:
    
    1 m
        Medium:
    
    Fish pellets
        Process temperature:
    
    0 … +30 °C
        Process pressure:
    
    0 … 0 bar
        Special challenges:
    
    Dust generation
Application
The pipes installed above the fish tanks enable demand-oriented, automatic feeding at any time of day. To this end, the storage tanks are continuously monitored to make sure they contain sufficient fish pellets and always get refilled on time. The tanks vary in size, depending on whether young fish or adult fish are involved.
                    Your benefit
Reliable
                                Reliable measurement right through the container walls
                            Cost effective
                                Efficient, demand-oriented feeding without running empty
                            User friendly
                                Retro-fit installation possible without opening the container
                            Recommended products
 
                                            VEGAPULS 31
Non-contact level measurement with radar in the storage tank
- Reliable measurement, unaffected by dust generation, because sensor measures right through the tank walls
- No contact with the fish feed thanks to non-contact measurement
- Convenient setup and commissioning with Bluetooth and VEGA Tools app
Measuring range - Distance
                                                            20 m
                                                            Process temperature
                                                            -40 ... 80 °C
                                                            Process pressure
                                                            -1 ... 3 bar
                                                             
                                            VEGAPOINT 31
Capacitive level switch as dry run protection in the storage tank
- Reliable detection ensures early refilling
- Easy installation without adjustment
- 360° status display for quick and easy recognition of switching status
Measuring range - Distance
                                                            -
                                                            Process temperature
                                                            -40 ... 115 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                             
                                    
                             
                                                    
                                            
Close