Gas storage tank
Volume and pressure monitoring in a gas storage tank
Process data
    Measuring task:
    
    Level and pressure measurement
        Measuring point:
    
    Container/pipeline
        Measuring range up to:
    
    0 … 30 m
        Medium:
    
    Gas
        Process temperature:
    
    0 … +50 °C
        Process pressure:
    
    0 … +10 bar
        Special challenges:
    
    Chemical resistance
Application
The hydrogen produced in the electrolyser is temporarily stored in a gas storage tank. Depending on the design of the gas storage tank, either a flexible diaphragm of plastic or a floating roof is used for volume equalization. The gas volume and gas pressure are measured continuously to ensure reliable and safe operation. 
                    Your benefit
Reliable
                                High measuring certainty without mechanical wear
                            Cost effective
                                Optimal information on the quantity of available gas
                            User friendly
                                Maintenance-free, reliable operation of the system
                            Recommended products
 
                                            VEGAPULS 6X
Continuous level measurement with radar for permanent gas volume measurement
- Maintenance-free operation using 80 GHz non-contact radar technology
- Exact measuring results, independent of medium, process and operating conditions
- Simple integration into existing gas storage tanks
- Wireless operation via Bluetooth with smartphone, tablet or PC
Measuring range - Distance
                                                            120 m
                                                            Process temperature
                                                            -196 ... 450 °C
                                                            Process pressure
                                                            -1 ... 160 bar
                                                             
                                            VEGABAR 82
Monitoring of the gas pressure in the gas reservoir
- High measuring accuracy through use of finely graduated measuring cells and measuring ranges
- Robust sensor construction for high availability
- Long-term stability of the ceramic measuring cell for maintenance-free operation
Measuring range - Distance
                                                            -
                                                            Measuring range - Pressure
                                                            -1 ... 100 bar
                                                            Process temperature
                                                            -40 ... 150 °C
                                                             
                                            VEGATRENN 141
Separator (supply isolator) for optimal power supply to connected sensors
- On-site diagnostics for immediate status display via LEDs
- Simple parameterisation interface via HART sockets for convenient operation
- Guarantees galvanic isolation between sensor and PLC
Protection rating
                                                            IP20
                                                            Input
                                                            1 x 4 … 20 mA/HART sensor input
                                                            Output
                                                            1 x 4 … 20 mA
                                                             
                                    
                             
                                                    
                                            
Close