Drying-cylinder
Differential pressure measurement in the drying cylinder
Process data
    Measuring task:
    
    Differential pressure measurement
        Measuring point:
    
    Drying cylinder
        Measuring range up to:
    
    0.5 bar
        Medium:
    
    Steam/condensate
        Process temperature:
    
    +95 … +150 °C
        Process pressure:
    
    +2 … +3 bar
        Special challenges:
    
    High temperatures and high humidity
Application
The residual moisture content of the paper web is removed by steam-heated cylinders in the drying section of the paper machine. The drying process removes heat from the steam, which then forms a thin layer of condensate on the inner walls of the cylinder. This layer influences the transfer of heat to the paper and has to be skimmed off continuously by siphoning. The correct level of heat transfer from the drying cylinder to the paper is monitored by pressure measurements both at the inlet and at the outlet.
                    Your benefit
Reliable
                                Reliable measurement ensures continuous, trouble-free operation of the facility
                            Cost effective
                                Low-cost measurement system via electronic differential pressure
                            User friendly
                                Simple installation, as capillaries and impulse lines are not necessary
                            Recommended products
 
                                            VEGABAR 82
Electronic differential pressure measurement at the inlet/outlet of the drying cylinder
- Long-term stability through use of dry CERTEC® measuring cell
- Direct pressure measurement without differential pressure lines
Measuring range - Distance
                                                            -
                                                            Measuring range - Pressure
                                                            -1 ... 100 bar
                                                            Process temperature
                                                            -40 ... 150 °C
                                                             
                                    
                             
                                                    
                                            
Close