Coke silo
Level measurement and point level detection in coke silos
Process data
    Measuring task:
    
    Level measurement and point level detection
        Measuring point:
    
    Silo
        Measuring range up to:
    
    25 m
        Medium:
    
    Coke
        Process temperature:
    
    -40 … +50 °C
        Process pressure:
    
    0 … 0 bar
        Special challenges:
    
    Heavy dust, abrasive medium
Application
Coke is often stored in very tall silos. Coke product is also susceptible to plugging the chute as the vessel empties. To accurately measure and monitor the level in these silos, especially during fill/empty stages, the instrumentation must be able to perform reliably, even under these conditions.
                    Your benefit
Reliable
                                Long measurement sensor lifespan because no contact with medium
                            Cost effective
                                Wear and maintenance-free
                            User friendly
                                Easy installation and setup
                            Recommended products
 
                                            VEGAPULS 6X
Radar sensor for continuous level measurement in coke silos
- Reliable measurement unaffected by buildup
- Radar principle is unaffected by temperature, gas and dust
- Non-contact measurement is wear and maintenance-free
Measuring range - Distance
                                                            120 m
                                                            Process temperature
                                                            -196 ... 450 °C
                                                            Process pressure
                                                            -1 ... 160 bar
                                                             
                                            VEGAMIP 61
Microwave barrier system for plugged chute detection of coke silo
- Non-contact measurement ensures maintenance-free service in abrasive media
- Reliable measurement, immune to dust and buildup
- Simple adjustment saves time and costs for setup
Measuring range - Distance
                                                            100 m
                                                            Process temperature
                                                            -40 ... 80 °C
                                                            Process pressure
                                                            -1 ... 4 bar
                                                             
                                    
                             
                                                    
                                            
Close