Sumps
Sump level control
Process data
    Measuring task:
    
    Level measurement
        Measuring point:
    
    Sump
        Measuring range up to:
    
    3 m
        Medium:
    
    Water and hydrocarbons
        Process temperature:
    
    -40 … +45 °C
        Process pressure:
    
    +1 … +3 bar
        Special challenges:
    
    Foam, buildup
Application
The level in the sumps around a refinery must be reliably monitored to prevent overfilling and subsequent pollution, or pump overload. Balanced pump utilization is possible thanks to a pump control rotation system integrated into the controller.
                    Your benefit
Reliable
                                Measurement optimizes pump usage via pump control functions
                            Cost effective
                                Pump control ensures energy conservation and long pump service life
                            User friendly
                                Easy setup and installation
                            Recommended products
 
                                            VEGAPULS 21
Radar sensor for continuous level measurement in sumps
- Very good signal focusing ensures accurate measurement, even in confined spaces
- Reliable measurement, unaffected by condensation on the antenna
- Maintenance-free operation thanks to non-contact measuring principle
Measuring range - Distance
                                                            20 m
                                                            Process temperature
                                                            -40 ... 80 °C
                                                            Process pressure
                                                            -1 ... 3 bar
                                                             
                                            VEGAMET 861
Controller for continuous lead-lag changeover control of pumps
- Integrated pump control function ensures longer pump service life
- Simple setup and installation reduces installation costs
Protection rating
                                                            IP66/IP67, Type 4X
                                                            Input
                                                            1 x 4 … 20 mA/HART sensor input
                                                                    2x digital input
                                                            Output
                                                            1 x 0/4 … 20 mA current output
                                                                    1x failure relay (instead of operating relay)
                                                                    4x operating relay
                                                             
                                    
                             
                                                    
                                            