Cargo tank in a bitumen tanker
Level measurement and point level detection in the cargo tanks of a bitumen tanker
Process data
    Measuring task:
    
    Level measurement and point level detection
        Measuring point:
    
    Tank
        Measuring range up to:
    
    15 m
        Medium:
    
    Bitumen
        Process temperature:
    
    +170 … +190 °C
        Process pressure:
    
    0 … 0 bar 
        Special challenges:
    
    High temperatures, chemically aggressive medium, condensation, highly viscous, heavy buildup, heating pipes at the tank bottom, ship approvals
Application
Bitumen is transported at temperatures of around 170 °C to 190 °C. The heating is supplied via an array of multi-layered heating tubes mounted on the floor and sides of the tanks. To ensure efficient utilisation of the tanks as well as a safe ship attitude, the levels in the bitumen tanks require accurate monitoring, particularly during loading and unloading.
                    Your benefit
Reliable
                                Reliable measurement solution for adhesive media
                            Cost effective
                                Accurate measurement of the tank contents, regardless of medium and degree of contamination
                            User friendly
                                Maintenance-free and reliable operation
                            Recommended products
 
                                            VEGACAP 64
Capacitive point level detection for overfill protection in the bitumen tank
- Proven, robust measuring principle, unaffected by high temperatures and buildup
- Reliable switch point allows optimum utilization of the tank volume
Measuring range - Distance
                                                            -
                                                            Process temperature
                                                            -50 ... 200 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                             
                                            VEGAPULS 6X
Radar sensor for non-contact level measurement in the bitumen tank
- Ideal for hot and adhesive media thanks to contactless measuring principle
- Front-flush antenna delivers precise measurement data even with heavy buildup
- High accuracy in all measuring situations
- Reliable measurement down to the bottom, even in difficult installation conditions thanks to the good focusing of 80 GHz technology
Measuring range - Distance
                                                            120 m
                                                            Process temperature
                                                            -196 ... 450 °C
                                                            Process pressure
                                                            -1 ... 160 bar
                                                             
                    