Heat recovery boiler
Level measurement and point level detection in the heat recovery boiler
Process data
    Measuring task:
    
    Level measurement and point level detection
        Measuring point:
    
    Tank
        Measuring range up to:
    
    3 m
        Medium:
    
    Water
        Process temperature:
    
    +300 ... +450 °C
        Process pressure:
    
    +100 … +160 bar
        Special challenges:
    
    Strong fluctuations of density, conductivity and dielectric constant of the hot water
Application
In the heat recovery boiler, hot process gas is passed through heating pipes. This means the gas is cooled and the necessary process heat for the plant recovered to be reused. To prevent the heat recovery boiler from running dry and thus overheating, reliable monitoring of the water level in the boiler is required. For maximum safety, the measurement is carried out redundantly with diverse instrument technology.
                    Your benefit
Reliable
                                Reliable function under all operating conditions
                            Cost effective
                                Maintenance-free instrumentation technology
                            User friendly
                                Automatic steam condensation
                            Recommended products
 
                                            VEGAFLEX 86
Continuous level measurement with guided radar in the heat recovery boiler
- Vapour compensation enables reliable measurement despite changing pressures and temperatures
- Special ceramic-graphite seal can be used up to 450 °C
- Available with SIL2 and boiler approvals for assured safety
Measuring range - Distance
                                                            75 m
                                                            Process temperature
                                                            -196 ... 450 °C
                                                            Process pressure
                                                            -1 ... 400 bar
                                                             
                                            VEGASWING 66
Vibrating level switch for reliable detection of minimum and maximum water level
- High level of safety via self-monitoring of sensor element and electronics at high process temperatures and pressures
- Redundant measurement for maximum safety
- Available with SIL2 and boiler approvals
- Fast and reliable function test by press of a button
Process temperature
                                                            -196 ... 450 °C
                                                            Process pressure
                                                            -1 ... 160 bar
                                                            Version
                                                            Compact version
                                                                    with gas-tight leadthrough
                                                                    with tube extension
                                                             
                                    
                             
                                                    
                                            