Blowdown drums
Level measurement and point level detection in the blowdown drums
Process data
Measuring task:
Level measurement and point level detection
Measuring point:
Tank
Measuring range up to:
10 m
Medium:
Various hydrocarbons
Process temperature:
+65 … +345 °C
Process pressure:
+1 … +20 bar
Special challenges:
High pressure, high temperature, changing products, very fast filling process
Application
The blowdown drum is designed to allow the refinery to release any process or byproduct liquids including hydrocarbons, in a safe and controlled way that protects plant equipment and personnel. The blowdown drum can see rapid filling at high pressures and temperatures. Because of the mixture of products, density and viscosity can also fluctuate, so the level must be measured quickly and reliably.
Your benefit
Reliable
Unaffected by density fluctuations, fast level, temperature and pressure changes
Cost effective
Maintenance-free operation
User friendly
Simple adjustment and installation
Recommended products
VEGAFLEX 86
Guided wave radar for continuous separation tracking of level and interface
- Robust mechanical construction is resistant to extreme process conditions
- Reliable measurement unaffected by product changes
- Flexible mounting options easily retrofit displacer bridles or installs directly in the vessel
Measuring range - Distance
75 m
Process temperature
-196 ... 450 °C
Process pressure
-1 ... 400 bar
VEGASWING X
Vibrating level switch as overfill protection device in containment receptacles
- Precise point level detection thanks to adjustment-free, media-independent switching point
- Reliable limit level detection unaffected by rapid temperature and pressure changes
- Maintenance-free operation increases system availability
Measuring range - Distance
-
Process temperature
-196 ... 450 °C
Process pressure
-1 ... 160 bar

Close