Process data
    Measuring task:
    
    Level measurement and point level detection
        Measuring point:
    
    Tank
        Measuring range up to:
    
    35 m
        Medium:
    
    Toxic liquid media
        Process temperature:
    
    -50 … +250 °C
        Process pressure:
    
    -1 … +64 bar
        Special challenges:
    
    Highly toxic media, chemically aggressive media, volatile media
Application
Some chemical processes generate extremely toxic intermediates that have to be stored under the most stringent security measures. In order to be used in this application, the measurement technology must meet specific requirements in terms of design and functional reliability. A redundant sealing concept, an optional glass feedthrough (Second Line of Defense) and highly resistant materials provide the necessary security for the storage and processing of toxic media.
                    Your benefit
Reliable
                                Configuration of the measuring system ensures maximum safety for people and the environment
                            Cost effective
                                High availability and maintenance-free operation
                            User friendly
                                Fast installation and simple setup
                            Recommended products
 
                                            VEGAPULS 6X
Continuous level measurement with radar in the storage tank for toxic media
- Non-contact measuring principle is independent of media properties
- Maximum safety with toxic media, thanks to ceramic process separation and additional glass sealing
- Highly resistant materials ensure a long service life
- Maintenance-free operation
Measuring range - Distance
                                                            120 m
                                                            Process temperature
                                                            -196 ... 450 °C
                                                            Process pressure
                                                            -1 ... 160 bar
                                                             
                                            VEGASWING 63
Vibrating level switch for point level detection in the storage tank for toxic media
- Universally applicable for almost all liquids
- Additional safety through glass seal that ensures even better separation from the process (Second Line of Defense)
- Simple setup without calibration
- Test button for easy testing of instrument functionality during operation
Process temperature
                                                            -50 ... 250 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                            Version
                                                            Standard
                                                                    Hygienic applications
                                                                    with gas-tight leadthrough
                                                                    with tube extension
                                                                    with temperature adapter
                                                             
                                    
                             
                                                    
                                            