Storage tank for milk and milk products
Level measurement and point level detection in the storage tank for milk and milk products
Process data
    Measuring task:
    
    Level measurement and level detection
        Measuring point:
    
    Tank
        Measuring range up to:
    
    5 m
        Medium:
    
    Milk and milk products
        Process temperature:
    
    0 … +80 °C
        Process pressure:
    
    +1 … +2 bar
        Special challenges:
    
    Cold media, frequent cleaning cycles, temperature shocks
Application
Milk and milk-based products such as cream, standard and pasteurized milk have to be stored in the correct quantities depending on production requirements. Since whole milk tends to separate into milk and cream even at low temperatures, it has to be circulated during storage. The quality of the milk must not be affected by stirring. To ensure that the circulation does not begin until the agitator is completely covered with product, a reliable measurement is required.
                    Your benefit
Reliable
                                Certified materials according to FDA and EC 1935/2004 regulations
                            Cost effective
                                Certified hygienic design of the sensors reduces cleaning time
                            User friendly
                                Very simple sensor installation
                            Recommended products
Solution 1
                Solution 2
         
                                            VEGABAR 82
Hydrostatic pressure transmitter for level measurement in storage tanks
- Easy to clean thanks to flush-mounted installation
- Reliable measurement, immune to the formation of condensation
- Robust measuring cell highly resistant to cleaning cycles
Measuring range - Distance
                                                            -
                                                            Measuring range - Pressure
                                                            -1 ... 100 bar
                                                            Process temperature
                                                            -40 ... 150 °C
                                                             
                                            VEGAPOINT 21
Capacitive level switch for detection of minimum and maximum levels
- Reliable switching point in all media
- Reliable measurement, immune to the formation of condensation
- Compact design facilitates cleaning
Measuring range - Distance
                                                            -
                                                            Process temperature
                                                            -40 ... 115 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                             
                                            VEGAPOINT 21
Capacitive level switch for detection of minimum and maximum levels
- Reliable switching point in all media
- Reliable measurement, immune to the formation of condensation
- Compact design facilitates cleaning
Measuring range - Distance
                                                            -
                                                            Process temperature
                                                            -40 ... 115 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                             
                                            VEGAPULS 6X
Non-contact level measurement with radar in storage tanks
- Strong focusing of radar beam enables exact measurement despite agitators
- Flange with encapsulated antenna system allows optimal CIP cleaning
- Reliable measurement during the filling process
Measuring range - Distance
                                                            120 m
                                                            Process temperature
                                                            -196 ... 450 °C
                                                            Process pressure
                                                            -1 ... 160 bar
                                                             
                                    
                             
                             
                                                    
                                             
                                            
Close