VEGAPULS 11
Compact radar sensor for continuous level measurement
For simple measuring tasks, plastic housing IP66/IP67, Type 4X
Application area
Your benefit
- High plant availability through non-contact measurement
- Exact measurement results independent of medium properties and process conditions
- Maintenance-free operation due to non-contact 80 GHz radar technology
Suitable accessories
Mounting bracket with adjustable sensor holder |
|
Mounting angle with adjustable bracket |
|
Universal flange for VEGAPULS BASIC line |
|
Further accessories |
Base price
Detailed information on prices and delivery times can be found in the Configurator.
Staggered Prices
Quantity | Price |
---|---|
from 1 | AU$ 950.00 |
from 5 | 10 % Discount |
from 10 | Please contact us! |
Product comparison
All documents and software for this product can be found in our Download Center.
Show all downloadsOther applications
- 8 m [Meter - Foot]
- -40 ... 60 °C [°C - °F]
- -1 ... 3 bar [Bar - kPa - psi]
- ± 5 mm / ± 0.2"
- 80 GHz
- 8°
- PVDF
- G1½, 1½ NPT, R1½
- FKM
- Plastic
- IP66/IP67, Type 4X
- 4 … 20 mA
- -40 ... 60 °C
- PC, PACTware and DTM
- Smartphone / Tablet / PC via Bluetooth
Drawing generator
Generate 2D and 3D drawings for your specific configuration.
Configure NowProduct catalog
Radar
Product information
VEGAPULS C 11, C 21, C 22, C 23, 11, 21, 31
Specification sheet
VEGAPULS 11
4 … 20 mA - two-wire
Operating instructions
VEGAPULS 11
4 … 20 mA - two-wire
Drawing generator
Further downloads for this product
All documents and software for this product can be found in our Download Center.
Show all downloadsMounting bracket with adjustable sensor holder
AU$ 140.00
Mounting angle with adjustable bracket
AU$ 240.00
Mounting bracket 200 mm with fixed sensor holder
AU$ 120.00
Hygienic adapter (G1½“) suitable for VEGAPULS 11, 21, 31, VEGAPULS C 11, C 21, C 22 and VEGAPULS Air 41
AU$ 170.00
Counter nut
Universal flange for VEGAPULS BASIC line
AU$ 160.00
Alignment device for vessel wall mounting for radar sensors with 1½" thread
AU$ 250.00
Threaded adapter 2" to 1½" suitable for VEGAPULS 11, 21, 31, VEGAPULS C 11, C 21, C 22 and VEGAPULS Air 41
AU$ 150.00
VEGAMET 141
1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
AU$ 720.00
VEGAMET 142
2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
AU$ 940.00
VEGAMET 341
1 x 4 … 20 mA sensor input, 1 x 4 … 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
AU$ 790.00
VEGAMET 342
2 x 4 … 20 mA sensor inputs, 2 x 4 … 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), Ex approval, separator, ship approval, on-site display, turn/push button and Smartphone operation
AU$ 1,000.00
VEGAMET 841
1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
AU$ 850.00
VEGAMET 842
2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
AU$ 1,070.00
VEGAMET 861
1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
AU$ 1,190.00
VEGAMET 862
2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
AU$ 1,430.00
VEGAMET 391
Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry
Show ProductVEGATOR 141
VEGATOR 142
VEGADIS 82
External measured value display and adjustment for 4 ... 20 mA/HART sensors
AU$ 430.00
VEGADIS 176
VEGAMET 841
1 x 4 ... 20 mA sensor input, 1 x 4 ... 20 mA current output, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
AU$ 850.00
VEGAMET 842
2 x 4 ... 20 mA sensor inputs, 2 x 4 ... 20 mA current outputs, 3 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
AU$ 1,070.00
VEGAMET 861
1 x 4 ... 20 mA/HART sensor input, 2 x digital inputs, 1 x 4 ... 20 mA current output, 4 x operating relay, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
AU$ 1,190.00
VEGAMET 862
2 x 4 ... 20 mA/HART sensor inputs, 4 x digital inputs, 3 x 4 ... 20 mA current outputs, 6 x operating relays, 1 x fail safe relay (instead of operating relay), on-site display, 4-button and smartphone operation
AU$ 1,430.00
VEGATRENN 141
VEGATRENN 142
VEGATRENN 151
Single channel separator in two-wire technology for 4 … 20 mA sensors
AU$ 240.00
VEGATRENN 152
Double channel separator in two-wire technology for 4 … 20 mA sensors
AU$ 350.00
An error has occurred
An error occurred when starting the configurator. We have documented the error and are working on it.
Please try again later. Alternatively you can contact us directly.
Thank you very much for your understanding.
VEGAPULS 11
myVEGA
With myVEGA as your personal information platform, you’ll have at your disposal numerous online functions revolving around the VEGA products.
- Configurator for the entire VEGA product range
- Information about prices and delivery times
- Order directly online
- Saving of configurations
- 2D/3D drawings of your configured instrument
- Overview of order transactions
Still no access?
Register for freeForgot password
Enter your e-mail address and we will send you a link to reset your password.
Reset password Cancel
Close