Osmosis filter
Differential pressure measurement in an osmosis filter
Process data
    Measuring task:
    
    Differential pressure measurement
        Measuring point:
    
    Filter
        Measuring range up to:
    
    +20 bar
        Medium:
    
    Sea water
        Process temperature:
    
    0 ... +25°C
        Process pressure:
    
    0 ... +20 bar
        Special challenges:
    
    Resistant to sea water
Application
Sea water is pressed through a semi-permeable membrane under high pressure. The semi-permeable membrane allows only water molecules to seep through. Salts, bacteria and viruses are retained in the filter. The finished product is almost the same as distilled water. A differential pressure measurement is needed to monitor the level of contamination across the filter.
                    Your benefit
Reliable
                                Approved materials according to FDA and EC 1935/2004, as well as local certification
                            Cost effective
                                Efficient cleaning of the filter is possible even during continuous operation
                            User friendly
                                Maintenance-friendly thanks to front-flush mounting
                            Recommended products
 
                                            VEGADIF 85
Differential pressure transmitter for measuring the level of contamination in the filter
- Highly accurate measurement of the smallest differential pressure
- High reliability with integrated overload diaphragm system
- Static pressure output also possible through integrated sensor for multi parameter measurement
Measuring range - Pressure
                                                            -40 ... 40 bar
                                                            Process temperature
                                                            -90 ... 400 °C
                                                            Process pressure
                                                            -1 ... 400 bar
                                                             
                                            VEGADIS 81
External display and adjustment unit for 4 ... 20 mA HART sensors
- Simple voltage supply of display via the existing 4 ... 20 mA current loop
- Easy-to-read display in plain text with additional graphical support menu
- Simple operation via four buttons and a clearly structured menu
Housing material
                                                            Plastic
                                                                    Aluminium
                                                                    Stainless steel (precision casting)
                                                            Protection rating
                                                            IP66/IP67
                                                            Ambient temperature
                                                            -20 ... 70 °C
                                                             
                                            Mounting bracket for VEGADIF
Mounting bracket for differential pressure transmitter
- Weatherproof and robust 304 stainless steel construction
- Simple wall or pipe mounting
 
                                    
                             
                                                    
                                            
Close