Storage tank for flocculant
Level measurement and point level detection in flocculant storage tanks
Process data
    Measuring task:
    
    Level measurement and point level detection
        Measuring point:
    
    Plastic tank
        Measuring range up to:
    
    3 m
        Medium:
    
    Variety of flocculants
        Process temperature:
    
    -40 … +60 °C
        Process pressure:
    
    0 … 0 bar
        Special challenges:
    
    Aggressive media
Application
The finest impurities in the water are bound together through flocculation. This allows the coagulated materials to be removed from the water by sedimentation or filtration. The flocculant required for such operation is stored in a reserve tank. A continuous level measurement ensures a sufficient supply of flocculants. The point level detection serves as overflow protection in the tank.
                    Your benefit
Reliable
                                Simple function test possible even during a running process
                            Cost effective
                                Ensures optimal supply of flocculants
                            User friendly
                                Simple calibration
                            Recommended products
 
                                            VEGAPULS 31
Flocculant storage tank level measurement with radar
- Maintenance-free operation through non-contact measurement
- Reliable level monitoring through the vessel top, thanks to strong focusing
- Universally applicable for different flocculants
Measuring range - Distance
                                                            20 m
                                                            Process temperature
                                                            -40 ... 80 °C
                                                            Process pressure
                                                            -1 ... 3 bar
                                                             
                                            VEGASWING 63
Point level detection with vibrating level switches for overfill protection
- Highly robust materials are resistant to aggressive media
- Fast and reliable function test by simply pressing a button
- Simple setup without adjustment
Process temperature
                                                            -50 ... 250 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                            Version
                                                            Standard
                                                                    Hygienic applications
                                                                    with gas-tight leadthrough
                                                                    with tube extension
                                                                    with temperature adapter
                                                             
                                    
                             
                                                    
                                            
Close