Condenser
Condenser pressure and point level measurement.
Process data
    Measuring task:
    
    Pressure and point level measurement
        Measuring point:
    
    Tank and pipeline
        Measuring range up to:
    
    +3.5 bar 
        Medium:
    
    Steam, water, cooling liquid
        Process temperature:
    
    +4 … +135 °C
        Process pressure:
    
    0 … +5 bar
        Special challenges:
    
    Influence from temperature, condensate formation
Application
In the condenser, potable water evaporated as steam and condensed to form pure, clean water . Inside the condenser there is a cooling system that cools the steam to make it condense. The feed of cooling liquid is monitored in the pipeline. Point level detection ensures that sufficient condensate is present to prevent steam from directly entering the circulation reservoir.
                    Your benefit
Reliable
                                The materials used do not interact with the medium.  
                            Cost effective
                                Maximum process efficiency is guaranteed through reliable measurement
                            User friendly
                                Standardized adapter system for all process fittings
                            Recommended products
 
                                            VEGABAR 83
Pressure transmitter for measurement in pipelines
- The materials used have no effect on the purified water.
- Good cleanability thanks to hygienic design
- Metallic measuring cell for front-flush pressure measurement, even at high temperatures
Measuring range - Distance
                                                            -
                                                            Measuring range - Pressure
                                                            -1 ... 1000 bar
                                                            Process temperature
                                                            -40 ... 200 °C
                                                             
                                            VEGABAR 28
Pressure transmitter for pressure measurement in the coolant inlet
- Ceramic CERTEC® measuring cell is resistant to aggressive cooling medium
- Reliable measurement, even with the formation of condensation, thanks to encapsulated measuring cell
- Compact design facilitates installation
Measuring range - Pressure
                                                            -1 ... 60 bar
                                                            Process temperature
                                                            -40 ... 130 °C
                                                            Accuracy
                                                            0.3 %
                                                             
                                            VEGAPOINT 21
Capacitive level switch for point level detection in the condenser
- Reliable switching point in water and steam
- Good cleanability thanks to hygienic design
- 360° visible display of the switching status
Measuring range - Distance
                                                            -
                                                            Process temperature
                                                            -40 ... 115 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                             
                                    
                             
                                                    
                                            
Close