Close

VEGACAL 62

Capacitive rod probe for continuous level measurement

Rod probe, partly PTFE insulated


Application area

For measurement of bulk solids and non-conductive liquids such as oil. A full/empty adjustment is necessary for setup.

The VEGACAL 62 is a level sensor for continuous level measurement in all industries. The partly insulated probe is designed for measurement of bulk solids and can be also used in non-conductive liquids such as e.g. oil. The proven construction offers high functional safety.

Your benefit

  • High flexibility through shortenable probe
  • Long lifetime and low maintenance requirement through robust mechanical construction
  • Maximum utilization of the vessel because measurement over the complete probe length

Configure product

Configure product
Application
Technical specifications
Documentation
Accessories
Configure product
Technical specifications
Measuring range - Distance
6 m
Process temperature
-50 ... 200 °C
Process pressure
-1 ... 64 bar
Version
with screening tube PN1
with concentric tube
Standard
Materials, wetted parts
PTFE
316L
Alloy 400 (2.4360)
PEEK
Steel C22.8
Threaded connection
≥ G½, ≥ ½ NPT
Flange connection
≥ DN25, ≥ 1"
Seal material
no media contact
Housing material
Plastic
Aluminium
Stainless steel (precision casting)
Stainless steel (electropolished)
Protection rating
IP66/IP68 (0,2 bar)
IP66/IP67
IP66/IP68 (1 bar)
Output
Profibus PA
Foundation Fieldbus
4 … 20 mA/HART - two-wire
Ambient temperature
-40 ... 80 °C
Approvals
Scope
ATEX / Europe
CSA / Canada
FM / USA
EAC (GOST) / Belarus
EAC (GOST) / Kazakhstan
EAC (GOST) / Russia
IEC / worldwide
KOSHA / Korea
NEPSI / China
UKR Sepro / Ukraine
INMETRO / Brazil
Explosion protection
Intrinsic safety Ex ia
Protection through housing St Ex
Foodstuffs/Pharma
FDA
Ship approval
ABS
BV
CCS
DNV
GL
LR
RINA
RMROS
Overfill protection
WHG
VLAREM II
SIL qualification
SIL2
Display & adjustment
Adjustment
PLICSCOM
PC, PACTware and DTM
HART-Communicator
Software (e. g. AMS™, PDM)
Indication
Display/adjustment module PLICSCOM
VEGADIS 81
VEGADIS 82

Drawing generator

Generate 2D and 3D drawings for your specific configuration.

Configure Now

Specification sheet

VEGACAL 62

4 … 20 mA/HART - two-wire

    • EN
    • DE
    • ES
    • FR
    • IT
    • NL
    • PT
    • RU
    • TR
    • US
    • ZH
Download

Product information

VEGACAL 62, 63, 64, 66, 69

    • EN
    • DE
    • ES
    • FR
    • IT
    • NL
    • PT
    • RU
    • US
    • ZH
Download

Product information

VEGACAL 62, 65, 66, 67

    • EN
    • DE
    • ES
    • FR
    • IT
    • NL
    • PT
    • RU
    • US
    • ZH
Download

Product catalog

Capacitive

    • EN
    • DE
    • CS
    • ES
    • FR
    • IT
    • NL
    • PT
    • RU
    • TR
    • ZH
Download

Operating instructions

VEGACAL 62

4 … 20 mA/HART - two-wire

    • EN
    • DE
    • CS
    • ES
    • FR
    • HU
    • IT
    • KK
    • NL
    • PL
    • PT
    • RU
    • TR
    • UK
    • ZH
Download

Drawing generator

Generate 2D and 3D drawings for your specific configuration.

Configure Now

Further downloads for this product

All documents and software for this product can be found in our Download Center.

Show all downloads
Indicating instruments
Controllers
Wireless communication
Components
Accessory
Spare parts
Our recommendation

PLICSCOM

PLICSCOM Steckbares Anzeige- und Bedienmodul

Measured value indication and adjustment of plics® sensors

Show Product

Bluetooth USB adapter

USB Dongle

Wireless adjustment of sensors and instruments via Bluetooth

Show Product

VEGADIS 81

VEGADIS-81-digital-display-adjustment-unit-VEGA-sensors

Remote measurement value indication and adjustment of plics® sensors

Show Product

VEGADIS 82

External measured value display and adjustment for 4 ... 20 mA/HART sensors

Show Product

VEGADIS 176

Remote display for use in 4 ... 20 mA current loop

Show Product

Magnetic pen for display/adjustment module PLICSCOM

PLICSCOM Magnet Pen

Magnetic pen for on-site adjustment

Show Product

VEGAMET 381

VEGAMET381EX Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren

Measured value display and simple control functions

Show Product

VEGAMET 391

VEGAMET391 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren

Measured value indication, simple control functions, remote enquiry of measured data. optimized for water/sewage water industry

Show Product

VEGAMET 624

VEGAMET625 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren.png	352 KB		 VEGAMET624 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren

Measured value indication, simple control functions such as remote enquiry of measured values for a 4 ... 20 mA/HART sensor

Show Product

VEGAMET 625

VEGAMET625 Auswertgeraet und Anzeigeinstrument fuer Fuellstandsensoren

Measured value indication, simple control functions such as remote enquiry of measured values for two HART sensors

Show Product

VEGASCAN 693

Signal conditioning instrument for up to 15 HART sensors

Measured value indication and remote enquiry of measured data for up to 15 HART sensors

Show Product

VEGATOR 141

Single channel signal conditioning instrument for level detection - 4 … 20 mA

Transmission of 4 ... 20 mA signals for level signalling

Show Product

VEGATOR 142

Double channel signal conditioning instrument for level detection - 4 … 20 mA

Transmission of 4 ... 20 mA signals for level signalling

Show Product

PLICSMOBILE T81

externe-GSM-GPRS-Funkeinheit

Measured data enquiry and remote parameter adjustment for a HART sensor

Show Product

VEGACONNECT

VEGACONNECT Schnittstellenadapter VEGACONNECT

Interface adapter between PC and VEGA instruments

Show Product

VEGABOX 03

Druckausgleichsgehäuse mit Belüftungsfilter

Breather housing with ventilation filter

Show Product

Modem antenna

Ethernet switch

Ethernet-Switch

up to 8 RS45 pluggable

Show Product

Profibus PA/DP segment coupler

Simple segment coupler for up to 93.75 kbit/s DP-side

Show Product

Seal adapter set for VEGACAL / VEGACAP 62, 63 and 64

Process fitting adapter VEGACAP/CAL60

Seal adapter set for VEGACAL / VEGACAP 62, 63 and 64

Electronics VEGACAL series 60

Process component VEGACAL 62

Loading device data
Configuration is being created
Loading configuration
An error occured while sending the last request. Please try again. ({{httpErrorStatusCode}})

An error has occurred

An error occurred when starting the configurator. We have documented the error and are working on it.
Please try again later. Alternatively you can contact us directly.

Thank you very much for your understanding.

### Einstellungen

Prices, delivery times & more

Log in to myVEGA to get the full functionality.

  • Prices & delivery times
  • Quotes & orders
  • 2D & 3D drawings
  • Save configurations

Register now