Process and ambient influences
Radar sensors are unaffected by temperature, pressure or vacuum and provide correct readings under all environmental conditions.
Read more ...
Dead zone and floodability
Radar sensors allow a safe measurement up to the sensor antenna, even in case of flooding.
Read more ...
Contamination and condensation
Radar sensors are insensitive to contamination and do not need to be cleaned.
Read more ...
Reliability and accuracy
Radar sensors can also be used in confined spaces and installations.
Read more ...
Do radar sensors also measure even at changing temperatures?
Do radar sensors also measure reliably when flooded?
Do radar sensors measure reliably even with contamination?
Level sensors VEGAPULS
With fixed cable connectionProtection IP66/IP68, Type 6P
|
With cable connection compartmentProtection IP66/IP67, Type 4X
|
VEGAPULS C 11
Measuring accuracy ± 5 mm
4 … 20 mA
VEGAPULS C 21
Measuring range up to 15 m
Measuring accuracy ± 2 mm
4 … 20 mA, HART, Modbus, SDI-12
Explosion protection
VEGAPULS C 22
Measuring range up to 15 m
Measuring accuracy ± 2 mm
4 … 20 mA, HART, Modbus, SDI-12
Explosion protection
VEGAPULS C 23
Measuring range up to 30 m
Measuring accuracy ± 2 mm
4 … 20 mA, HART, Modbus, SDI-12
Explosion protection
VEGAPULS 11
Measuring accuracy ± 5 mm
4 … 20 mA
VEGAPULS 21
Measuring accuracy ± 2 mm
4 … 20 mA, HART
Explosion protection
VEGAPULS 31
Measuring range up to 15 m
Measuring accuracy ± 2 mm
4 … 20 mA, HART
Explosion protection
With display
New heart for radar sensors
- Optimized for the reflection properties of different media
- Smallest design for the construction of compact sensor technology
- 80 GHz technology for a very good Signal focusing
- High accuracy in wide temperature ranges
- Low energy consumption optimized for level measurement
- Integrated function monitoring reduces maintenance costs
Controllers
VEGAMET 141, 142for analogue sensors
rail mounting |
VEGAMET 341, 342for analogue sensors
panel mounting |
VEGAMET 841, 842, 861, 862for analogue and digital sensors |
VEGAMET 141
1x 4 … 20 mA
Output:
1x 0/4 … 20 mA current output,
3x operating relay
VEGAMET 142
2x 4 … 20 mA sensor input
Output:
2x 0/4 … 20 mA current output,
3x operating relay
VEGAMET 341
1x 4 … 20 mA
Output:
1x 0/4 … 20 mA current output,
3x operating relay
VEGAMET 342
2x 4 … 20 mA sensor input
Output:
2x 0/4 … 20 mA current output,
3x operating relay
VEGAMET 841
1x 4 … 20 mA sensor input
Output:
1x 0/4 … 20 mA current output
3x operating relay
VEGAMET 842
2x 4 … 20 mA sensor input
Output:
2x 0/4 … 20 mA current output
3x operating relay
VEGAMET 861
1x 4 … 20 mA/HART sensor input
2x digital input
Output:
1x 0/4 … 20 mA current output
4x operating relay
VEGAMET 862
2x 4 … 20 mA/HART sensor input,
4x digital input
Output:
3x 0/4 … 20 mA current output
6x operating relay
Wireless adjustment
myVEGA
With myVEGA as your personal information platform you have access to numerous online functions relating to the VEGA products.
- 2D/3D drawings of configured instruments
- Access to product documentation and order data
- Access codes for VEGA sensors
Brochure radar is the better ultrasonic