Level and interface measurement and point level detection in separators
Process data
    Measuring task:
    
    Level and interface measurement, point level detection
        Measuring point:
    
    Tank
        Measuring range up to:
    
    3 m
        Medium:
    
    Hydrocarbons and water
        Process temperature:
    
    +25 … +200 °C
        Process pressure:
    
    +1 … +40 bar
        Special challenges:
    
    Changing media properties and emulsions
Application
Exact interface measurement in separators is important for ensuring the quality of the separation process. Continuous control of the interface between oil and water ensures that oil is not inadvertently withdrawn instead of water. This saves costs and increases the efficiency of the plant. A vibrating level switch serves as an additional overfill protection mechanism.
                    Your benefit
Reliable
                                Redundant measurement for highest safety standards
                            Cost effective
                                Maintenance-free operation
                            User friendly
                                Easy installation
                            Recommended products
 
                                            VEGASWING 63
Vibrating level switch for overfill protection in separators
- Additional security thanks to diverse redundancy
- Easy setup without medium saves time and money
- Increased plant availability, as function test can be performed during operation
Process temperature
                                                            -50 ... 250 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                            Version
                                                            Standard
                                                                    Hygienic applications
                                                                    with gas-tight leadthrough
                                                                    with tube extension
                                                                    with temperature adapter
                                                             
                                            VEGAFLEX 81 and magnetic level indicator
Guided wave radar and magnetic level indicator for level and interface measurement
- Redundant measurement through the combination of guided radar sensor and magnetic level indicator
- Evaluation of two different measured values possible: level and interface
- Totally reliable measurement, even with emulsions
Measuring range - Distance
                                                            75 m
                                                            Process temperature
                                                            -60 ... 200 °C
                                                            Process pressure
                                                            -1 ... 40 bar