Molten salt storage in a thermal solar plant
Level measurement in the molten salt storage tank
Process data
    Measuring task:
    
    Level measurement
        Measuring point:
    
    Tank
        Measuring range up to:
    
    30 m
        Medium:
    
    Molten salt
        Process temperature:
    
    +300 … +400 °C
        Process pressure:
    
    0 … 0 bar 
        Special challenges:
    
    High temperatures, density changes
Application
The important criterion for the location a thermal solar plant is gaining the optimal amount of sunlight energy available at that site over the year. Molten salt is used to store this thermal energy produced on the days when there is abundant sunshine, this enables the production of electricity even on days with little or no direct sunlight via a heat exchange process.  This molten salt is usually stored in two large vessels. One vessel contains salt at a lower temperature (approx. 300° C), the other contains salt at a higher temperature (approx. 400° C). Accurate level measurement is essential to monitor the system capacity.
                    Your benefit
Reliable
                                Reliable level measurement ensures smooth operation
                            Cost effective
                                Large storage reserves available through optimal utilization of tank volume
                            User friendly
                                Maintenance-free through non-contact measuring method
                            Recommended products
 
                                            VEGAPULS 6X
Non-contact level measurement with radar in a molten salt storage tank.
- High measuring precision, independent of product properties
- Reliable measurement for extremely high temperature ranges
- Maintenance free due to contactless measurement
 
Measuring range - Distance
                                                            120 m
                                                            Process temperature
                                                            -196 ... 450 °C
                                                            Process pressure
                                                            -1 ... 160 bar
                                                             
                    
Close