Distillation vessel
Level measurement in a distillation vessel and pressure monitoring in the supply line
Process data
    Measuring task:
    
    Level and pressure measurement
        Measuring point:
    
    Tank
        Measuring range up to:
    
    3 m
        Medium:
    
    Solvent/water mixture
        Process temperature:
    
    +40 ... +60 °C
        Process pressure:
    
    -1 … +3 bar
        Special challenges:
    
    Foam
Application
Solvents are used in the pharmaceutical industry for extracting active ingredients. They are then recovered via evaporation in a high-vacuum distillation vessel. After the solvent has been removed from the pharmaceutical product by evaporation, it is further processed. Reliable level measurement is required in the distillation vessel for process control.
                    Your benefit
Reliable
                                Optimised distillation process through a reliable measurement
                            Cost effective
                                Simple installation saves time and costs
                            User friendly
                                Output of additional measured values
                            Recommended products
 
                                            VEGABAR 82
Electronic differential pressure measurement for level measurement in a distillation vessel
- Reliable measuring results safeguard the distillation process
- Robust and drift-free, thanks to oil-free CERTEC® ceramic measuring cell
- Reliable level measurement, unaffected by foam generation
- Additional measured values such as vacuum and temperature
Measuring range - Distance
                                                            -
                                                            Measuring range - Pressure
                                                            -1 ... 100 bar
                                                            Process temperature
                                                            -40 ... 150 °C
                                                             
                                            VEGABAR 38
Pressure monitoring with IO-Link connection in the supply line of the heating medium
- Reliable measurement thanks to fast response time
- Robust ceramic CERTEC® measuring cell guarantees a long service life
- Simple operation thanks to VDMA menu structure and integrated display
Measuring range - Pressure
                                                            -1 ... 60 bar
                                                            Process temperature
                                                            -40 ... 130 °C
                                                            Accuracy
                                                            0.3 %
                                                             
                                    
                             
                                                    
                                            