Fluidized bed reactor
Level measurement and filter monitoring in granulate production in the fluidized bed process
Process data
    Measuring task:
    
    Level measurement and filter monitoring
        Measuring point:
    
    Reactor
        Measuring range up to:
    
    10 m
        Medium:
    
    Water and granulate
        Process temperature:
    
    +20…+150° C
        Process pressure:
    
    -1 … +10 bar
        Special challenges:
    
    Abrasive media
Application
One method for producing and drying granulates is the fluidized bed process. A uniform stream of air is fed up through a distributor plate at the bottom of the fluidized bed reactor. A liquid granule suspension is sprayed in from above, in the air stream it turns into solid granulate and collects on the top of distributor plate and the exhaust air flows through a filter for cleaning. To ensure a high-quality process, both the granulate quantity on the distributor plate and the condition of the filter must be permanently monitored. The measurement technology must also fulfil the most stringent hygienic requirements in order to guarantee a consistently high granulate quality.
                    Your benefit
Reliable
                                Certified hygienic design (3A/EHEDG) and approved materials according to EC 1935/2004 and FDA
                            Cost effective
                                Three instruments, four measured values:  pressure (vessel and line), granulate level and temperature
                            User friendly
                                Process data storable and transferable
                            Recommended products
 
                                            VEGABAR 82
Pressure transmitter for filter monitoring and level measurement in granulation in the fluidized bed process
- High resistance to abrasive particles with ceramic CERTEC® diaphragm
- Maximum reliability and operating safety
- Front-flush process fittings allow optimal CIP and SIP cleaning and ensure reliable production
Measuring range - Distance
                                                            -
                                                            Measuring range - Pressure
                                                            -1 ... 100 bar
                                                            Process temperature
                                                            -40 ... 150 °C
                                                             
                                    
                             
                                                    
                                            
Close