Hydrogen tanker with liquid hydrogen
Level measurement in a liquid hydrogen tank
Process data
    Measuring task:
    
    Level measurement
        Measuring point:
    
    Tank
        Measuring range up to:
    
    15 m
        Medium:
    
    Liquid hydrogen
        Process temperature:
    
    -253 ... -251 °C
        Process pressure:
    
    0 ... +1 bar
        Special challenges:
    
    Low density, low dielectric constant, outgassing of the medium
Application
If energy-rich hydrogen has to be transported over long distances, special tanker ships are used. To minimise losses, the hydrogen is cooled down to -253 °C at 1 bar pressure so that it can be stored in liquid form. The level can be measured either by means of thin impulse lines and conventional differential pressure or free-radiating radar. An elaborate standpipe, which would also lead to increased heat input, is not required.
                    Your benefit
Reliable
                                Highly accurate measurement of even low-density materials
                            Cost effective
                                Precise level measurement for optimal storage
                            User friendly
                                Simple installation without standpipe
                            Recommended products
Solution 1
                Solution 2
         
                                            VEGADIF 85
Level measurement via differential pressure in a tank holding liquid hydrogen
- Reliable measurement thanks to diaphragm with gold coating
- Precise measured values, even with very low hydrostatic pressures
- Output of differential as well as static pressure through a second current output
Measuring range - Pressure
                                                            -40 ... 40 bar
                                                            Process temperature
                                                            -90 ... 400 °C
                                                            Process pressure
                                                            -1 ... 400 bar
                                                             
                                            VEGAPULS 6X
Level measurement with radar in a tank holding liquid hydrogen
- Reliable measurement even at extremely low product temperatures
- Exact measurement despite low dielectric constant of liquid hydrogen
- No installation of a standpipe necessary
Measuring range - Distance
                                                            120 m
                                                            Process temperature
                                                            -196 ... 450 °C
                                                            Process pressure
                                                            -1 ... 160 bar
                                                             
                             
                             
                                             
                                            