VEGACAL 66

Capacitive cable probe for continuous level measurement

Cable probe, fully PTFE insulated


Application area

For use in non-abrasive liquids and bulk solids. The cable probe is fully insulated. A full/empty adjustment is necessary for setup.
The VEGACAL 66 is a level sensor for use in non-abrasive liquids and bulk solids. The cable probe is fully insulated. The proven mechanical construction offers high functional safety.

Your benefit

  • Savings through simple mounting and setup
  • Long lifetime and low maintenance requirement through robust mechanical construction
  • Maximum utilization of the vessel because measurement over the complete probe length

Configure product

Configure product
Technical specifications
Documentation
Accessories
Configure product
Technical specifications
Measuring range - Distance
  • 32 m [Meter - Foot]
Process temperature
  • -50 ... 150 °C [°C - °F]
Process pressure
  • -1 ... 40 bar [Bar - kPa - psi]
Version
  • PTFE insulated cable ø 8 mm with gravity weight
  • PTFE-insulated cable ø 8 mm with gravity weight and screening tube
Materials, wetted parts
  • PTFE
  • 316L
  • Steel C22.8
Threaded connection
  • ≥ G1, ≥ 1 NPT
Flange connection
  • ≥ DN50, ≥ 2"
Seal material
  • no media contact
Housing material
  • Plastic
  • Aluminium
  • Stainless steel (precision casting)
  • Stainless steel (electropolished)
Protection rating
  • IP66/IP68 (0,2 bar)
  • IP66/IP67
  • IP66/IP68 (1 bar)
Output
  • Profibus PA
  • Foundation Fieldbus
  • Two-wire: 4 … 20 mA/HART
Ambient temperature
  • -40 ... 80 °C
Approvals
Scope
  • ATEX / Europe
  • FM / USA
  • EAC (GOST) / Belarus
  • EAC (GOST) / Kazakhstan
  • EAC (GOST) / Russia
  • IEC / worldwide
  • KOSHA / Korea
  • NEPSI / China
  • UKR Sepro / Ukraine
  • INMETRO / Brazil
  • CSA / USA and Canada
Explosion protection
  • Intrinsic safety "i"
  • Flameproof enclosure "d"
  • Dust ignition protection "t"
Ship approval
  • ABS
  • BV
  • CCS
  • DNV
  • LR
  • RINA
  • RMROS
Overfill protection
  • WHG
  • VLAREM II
SIL qualification
  • SIL2
Display & adjustment
Adjustment
  • PLICSCOM
  • PC, PACTware and DTM
  • HART-Communicator
  • Software (e. g. AMS™, PDM)
Indication
  • Display/adjustment module PLICSCOM
  • VEGADIS 81
  • VEGADIS 82