Propane storage in bullets and spheres
Level measurement and pressure monitoring of liquefied gases in storage
Process data
    Measuring task:
    
    Level and pressure measurement
        Measuring point:
    
    Bullet tank
        Measuring range up to:
    
    4 m
        Medium:
    
    Liquid propane
        Process temperature:
    
    -40 … +50 °C
        Process pressure:
    
    +3 … +10 bar
        Special challenges:
    
    Low dielectric constant
Application
Propane, a flammable, colourless and odourless gas, is one of the many types of liquefied petroleum gases (LPG) that exist. It is produced from natural gas via a special refining process. Propane is compressed, liquefied and stored in pressure vessels so that it does not return to a gaseous state. To ensure optimal storage, reliable level measurement is required.
                    Your benefit
Reliable
                                High measuring accuracy despite low dielectric constants
                            Cost effective
                                Maintenance-free operation
                            User friendly
                                Easy installation and setup
                            Recommended products
 
                                            VEGABAR 83
Pressure transmitter for pressure monitoring in spherical tanks
- Universally applicable, fully welded measuring cells for direct connection to process
- A variety of process fittings always enables an appropriate adaptation to the container
- SIL conformity in accordance with IEC 61508, in a single-channel architecture up to SIL2 and in a multi-channel architecture up to SIL3
- Extremely robust measuring cells of Alloy, for higher safety during operation
Measuring range - Distance
                                                            -
                                                            Measuring range - Pressure
                                                            -1 ... 1000 bar
                                                            Process temperature
                                                            -40 ... 200 °C
                                                             
                                            VEGAPULS 6X
Level measurement with radar in spherical tanks
- Maintenance-free operation thanks to non-contact measuring principle
- High measuring accuracy even with low dielectric constants
- Very narrow signal focusing even in large measuring ranges
- The sensor is simple and easy to replace thanks to cut-off valve and isolation from process
Measuring range - Distance
                                                            120 m
                                                            Process temperature
                                                            -196 ... 450 °C
                                                            Process pressure
                                                            -1 ... 160 bar
                                                             
                                    
                             
                                                    
                                            
Close