Filter system for coarse dirt
Differential pressure measurement and point level detection in filter systems
Process data
    Measuring task:
    
    Differential pressure and limit level measurement
        Measuring point:
    
    Pipeline and tank
        Measuring range up to:
    
    0 … +5 bar
        Medium:
    
    Dirty water
        Process temperature:
    
    0 … +30 °C
        Process pressure:
    
    0 … +5 bar
        Special challenges:
    
    Contamination resistant
Application
In on-shore facilities, reliable filtration ensures the required water quality. This is achieved through the use of mechanical drum and disc filters. They form a multi-stage system, where automatic flushing via jet nozzles is controlled by the water level in the tank. Besides a high water quality, the fish also need the right amount of oxygen in the water. After the water has been cleaned, the correct amount of oxygen is added to it via compressors. Throughout the entire process, a guaranteed flow of water with sufficient oxygen enrichment is essential and therefore ensured by reliable differential pressure measurement and limit level detection.
                    Your benefit
Reliable
                                Reliable measurement even with buildup
                            Cost effective
                                Optimal cleaning thanks to flush design
                            User friendly
                                Configuration with smartphone or PC via wireless operation with Bluetooth
                            Recommended products
 
                                            VEGABAR 82
Electronic differential pressure measurement in filter systems
- Low costs for maintenance thanks to wear-free ceramic measuring cell
- Long-term stable and reliable thanks to moisture-proof measuring cell
Measuring range - Distance
                                                            -
                                                            Measuring range - Pressure
                                                            -1 ... 100 bar
                                                            Process temperature
                                                            -40 ... 150 °C
                                                             
                                            VEGAPOINT 24
Capacitive level switch as dry run protection
- Reliable switching point, insensitive to build up
- Simple setup without adjustment
- 360° status display for quick and easy recognition of switching status
Measuring range - Distance
                                                            -
                                                            Process temperature
                                                            -40 ... 115 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                             
                                    
                             
                                                    
                                            
Close