Conveyor belt transfer station
Level measurement and point level detection at the belt transfer point
Process data
    Measuring task:
    
    Level measurement and point level detection
        Measuring point:
    
    Silo 
        Measuring range up to:
    
    5 m
        Medium:
    
    Stones, gravel and sand
        Process temperature:
    
    -40 … +50 °C
        Process pressure:
    
    0 … 0 bar
        Special challenges:
    
    Extremely noisy and dusty environment, abrasion
Application
The transport of coarse and fine bulk solids within a stone processing facility takes place in most cases via conveyor belts. To achieve an even throughput and compensate for volume fluctuations during transport, belt transfer points are integrated in the conveyor line. The incoming bulk material is briefly stored in a buffer silo to prevent belt overfilling. This is the point where the level and the point level must be monitored.
                    Your benefit
Reliable
                                Reliable monitoring of silo filling
                            Cost effective
                                Optimal utilization of conveyor belt capacity
                            User friendly
                                Maintenance-free operation
                            Recommended products
Radar, Capacitive
                Radar, Microwave barrier
         
                                            VEGAPULS 6X
Non-contact level measurement with radar at the belt transfer station
- Highly reliable even in dusty environments
- Maintenance-free non-contact measurement
- Maximum operational reliability due to noise insensitivity
Measuring range - Distance
                                                            120 m
                                                            Process temperature
                                                            -196 ... 450 °C
                                                            Process pressure
                                                            -1 ... 160 bar
                                                             
                                            VEGACAP 65
Overfill protection with capacitive point level detection at the belt transfer station
- Reliable measuring results, unaffected by buildup
- Dependable switching point ensured by large gravity weight
- Long service life thanks to robust, cut to length cable probe
Measuring range - Distance
                                                            -
                                                            Process temperature
                                                            -50 ... 200 °C
                                                            Process pressure
                                                            -1 ... 64 bar
                                                             
                                            VEGAMIP 61
Microwave barrier for level detection at the belt transfer point
- High measurement certainty even with soiling and deposits
- Long service life ensured by robust sensor
- Maintenance-free operation with non-contact measuring principle
Measuring range - Distance
                                                            100 m
                                                            Process temperature
                                                            -40 ... 80 °C
                                                            Process pressure
                                                            -1 ... 4 bar
                                                             
                             
                             
                                             
                                            
Close