Ice cream "Premix" mixer
Level and pressure measurement during the mixing of ice cream ingredients
Process data
    Measuring task:
    
    Level and pressure measurement
        Measuring point:
    
    Tank/pipe
        Measuring range up to:
    
    1.5 m
        Medium:
    
    Ice cream
        Process temperature:
    
    0 … +125 °C
        Process pressure:
    
    -1 … +5 bar 
        Special challenges:
    
    Large temperature fluctuations, condensate
Application
The ingredients for making ice cream are accurately weighed and fed into a mixing tank, where the "premix" is made. Afterwards, the premix is passed through the homogenizer at a pressure of about 140 bar and then pasteurized at 80 °C. The level in the premix vessel and the pressure in the pipeline leading to the homogenizer need to be continuously monitored to ensure continuous ice cream production.
                    Your benefit
Reliable
                                Certified materials according to FDA and EC 1935/2004 regulations
                            Cost effective
                                Short delivery time and standardized operation thanks to plics® concept
                            User friendly
                                Simple installation due to small dimensions
                            Recommended products
 
                                            VEGAPULS 42
Continuous level measurement with radar in the “premix“
- Non-contact measurement, independent of agitators due to tight focussing, even in the smallest of containers
- Compact design allows installation even in very small vessels
- Reliable measurement, immune to the formation of condensation
Measuring range - Distance
                                                            15 m
                                                            Process temperature
                                                            -40 ... 130 °C
                                                            Process pressure
                                                            -1 ... 16 bar
                                                             
                                            VEGABAR 83
Pressure transmitter for monitoring pressure in a homogenizer
- Robust diaphragm easily handles high pressures
- Resistant to vacuum during the cleaning cycle
Measuring range - Distance
                                                            -
                                                            Measuring range - Pressure
                                                            -1 ... 1000 bar
                                                            Process temperature
                                                            -40 ... 200 °C
                                                             
                    
Close