VEGASWING 63

Vibrating level switch with tube extension for liquids

For liquids (density: > 0.5 ... 2.5 g/cm³) – with tube extension


Application area

The position of the switching point can be up to 6 m away from the installation site. Numerous process fittings, approvals as well as housing and electronics versions.
VEGASWING 63 is used as a universal level switch in all liquids. Independent of the mounting position it detects reliably with millimetre accuracy the level. The instrument can be used in vessels as empty or full detector, as approved overfill protection, dry run protection or pump protection. The position of the switching point is determined through the tube extension. The VEGASWING 63 offers high reliability and security in a wide application range.

Your benefit

  • Precise and reliable function due to product-independent switching point
  • Low maintenance costs
  • Minimum time and cost expenditure thanks to simple setup without medium

Configure product

Configure product

All documents and software for this product can be found in our Download Center.

Show all downloads
Application
Technical specifications
Documentation
Accessories
Configure product

Other applications

Turbine building in the hydroelectric power plant

Level and point level detection in the seepage water shaft

Level and point level detection in the seepage water shaft

To the application

Tanks for solvents

Level measurement, point level and pressure measurement in the storage and transfer of solvents

Level measurement, point level and pressure measurement in the storage and transfer of solvents

To the application

Holding tanks

Level measurement and point level detection of holding tanks

Level measurement and point level detection of holding tanks

To the application

BTX separators

Level measurement and point level detection in the BTX separators

Level measurement and point level detection in the BTX separators

To the application
Technical specifications
Process temperature
-50 ... 250 °C [°C - °F]
Process pressure
-1 ... 64 bar [Bar - kPa - psi]
Version
Standard
Hygienic applications
with gas-tight leadthrough
with tube extension
with temperature adapter
Materials, wetted parts
PFA
316L
Alloy C22 (2.4602)
Alloy 400 (2.4360)
ECTFE
Enamel
Threaded connection
≥ G¾, ≥ ¾ NPT
Flange connection
≥ DN25, ≥ 1"
Hygenic fittings
Clamp ≥ 1" - DIN32676, ISO2852
Slotted nut ≥ 1½", ≥ DN40 - DIN 11851
Varivent ≥ DN25
hygienic fitting F40 with compression nut
SMS 1145 DN51
SMS DN38
Hygienic fittings ≥ DN25 - DIN11864-1-A
Hygienic flange connection DIN11864-2-A; DN60(ISO)ø60,3
SMS socket piece DN38 PN6
Seal material
no media contact
Housing material
Plastic
Aluminium
Stainless steel (precision casting)
Stainless steel (electropolished)
Protection rating
IP66/IP67
IP66/IP68 (1 bar)
IP65
Output
Relay (DPDT)
Contactless electronic switch
Transistor (NPN/PNP)
Two-wire
NAMUR
Ambient temperature
-40 ... 70 °C
Approvals
Scope
ATEX / Europe
CSA / Canada
FM / USA
EAC (GOST) / Belarus
EAC (GOST) / Kazakhstan
EAC (GOST) / Russia
IEC / worldwide
KOSHA / Korea
NEPSI / China
UKR Sepro / Ukraine
INMETRO / Brazil
CCOE / India
Explosion protection
Intrinsic safety "i"
Flameproof enclosure "d"
Dust explosion protection through housing "t"
Foodstuffs/Pharma
3A
EHEDG
FDA
Ship approval
ABS
BV
CCS
DNV
GL
LR
RINA
RMROS
Overfill protection
WHG
VLAREM II
SIL qualification
SIL2
Display & adjustment
Indication
Pluggable display module PLICSLED

Drawing generator

Generate 2D and 3D drawings for your specific configuration.

Configure Now

Product catalog

Vibration

    • EN
    • DE
    • CS
    • ES
    • FR
    • IT
    • NL
    • PL
    • PT
    • TR
    • ZH
Download

Product information

VEGASWING 51, 53, 61, 63, 66

    • EN
    • US
    • DE
    • ES
    • FR
    • IT
    • NL
    • PL
    • PT
    • TR
    • ZH
Download

Specification sheet

VEGASWING 63

Relay (DPDT)

    • EN
    • US
    • DE
    • ES
    • FR
    • IT
    • NL
    • PT
    • TR
    • ZH
Download

Operating instructions

VEGASWING 63

Relay (DPDT)

    • EN
    • DE
    • CS
    • DA
    • ES
    • FI
    • FR
    • HU
    • IT
    • KK
    • KO
    • NL
    • NO
    • PL
    • PT
    • SV
    • TR
    • UK
    • ZH
Download

Drawing generator

Generate 2D and 3D drawings for your specific configuration.

Configure Now

Further downloads for this product

All documents and software for this product can be found in our Download Center.

Show all downloads
Indicating instruments
Controllers
Accessory
Spare parts

PLICSLED

PLICSLED-off

Universal display module suitable for all sensors of the VEGA plics® family with relay output

Show Product

VEGATOR 111

Single channel signal conditioning instrument acc. to NAMUR

Transmission of NAMUR signals for level signalling

$ 170.00

Base price

Show Product

VEGATOR 112

Double channel signal conditioning instrument acc. to NAMUR

Transmission of NAMUR signals for level signalling

$ 253.00

Base price

Show Product

VEGATOR 121

Single channel signal conditioning instrument for level detection - Two-wire 8/16 mA

Transmission of 8/16 mA signals for level signalling

$ 524.00

Base price

Show Product

VEGATOR 122

Double channel signal conditioning instrument for level detection - Two-wire 8/16 mA

Transmission of 8/16 mA signals for level signalling

$ 694.00

Base price

Show Product

Lock fitting for VEGASWING 63

Lock fitting VEGASWING

With the lock fittings, sensors with tube extension can be fixed infinitely.

Show Product

Welded socket VEGASWING 61/63

Welded sockets are used to connect the sensors to the process.

Show Product

Reduction flange enamelled

Electronics VEGASWING 61 and 63

Process component VEGASWING 63

Loading device data
Configuration is being created
Loading configuration
Want to pick up where you left off?
Your latest configuration
{{lastConfiguration.code}}
{{getLastConfigurationDate()}}
Open configuration
An error occured while sending the last request. Please try again. ({{httpErrorStatusCode}})

An error has occurred

An error occurred when starting the configurator. We have documented the error and are working on it.
Please try again later. Alternatively you can contact us directly.

Thank you very much for your understanding.

Settings
{{subGroup.subGroupName}}
Go to: {{activeGroup.nextGroup.groupName}}